18
GB
O R I G I N A L I N S T R U C T I O N S
Periodical revisions
It is required to carry out periodical revisions and maintenance of the subassemblies of the generator mentioned below.
NOTE!
All maintenance actions must be realised when the device is turned off and not functioning. It is also required to disconnect
any electrical devices from the generator.
NOTE!
If any service action is not described below, then the in order to have the action in question carried out, the device must
be sent to a specialist service shop.
NOTE!
If the device is cleaned with a solvent, any contact of the solvent with the skin and the eyes must be avoided. Use personal
protection means.
Element
Remarks
Before each start-up
After the first month
of operation or after
the first 10 hours of
operation
Every 3 months or
every 50 hours of
operation
Every 6 months or
every 100 hours of
operation
Every 12 months or
every 300 hours of
operation
Oil level in the
engine gear
Check
X
Replace
X
X
Air filter
Check
X
Clean
X(*)
Spark plug
Cleaning. If
necessary, replace it
X
Fuel inlet filter
Check. If necessary,
replace it.
X
Fuel system
Revision of tightness
and possible
damage.
X
Replace
Every two years
Removal of carbon
residues
Check more often, if
necessary
X
Engine
Cleaning and
adjustments of the
valves and cylinders
X
(*) In case the generator is operated in a dusty atmosphere, a higher frequency is recommended.
It is recommended to replace the fuel tank every three years. If any leakage of the fuel installation is detected then it is prohibited
to operate the generator.
Maintenance of the air filter
NOTE! It is prohibited to operate the generator if the air filter is not installed.
Maintenance actions of the air filter must be carried out in accordance with the procedure indicated in „PREPARATIONS FOR
OPERATION”.
Maintenance of the spark plug
Open the access panel to the spark plug. (XI)
Disconnect the cable from the spark plug.
Remove the spark plug using the spark plug wrench. (XI)
Clean the electrodes with a wire brush.
Check the distance between the electrodes, which should amount to 0.7 mm to 0.8 mm. (XII)
In case the electrodes are burnt or the ceramic protection is broken, the spark plug must be replaced with a new one.
Install the spark plug.
Connect the cable to the spark plug. Close the access panel.
Maintenance of the fuel filter
Dismantle the fuel inlet cover.
Remove the fuel inlet filter. (XIII)
Clean the fuel inlet filter using compressed air.
Remove the fuel filter cover and clean it thoroughly of the residues of fuel and contamination.
If required replace the gasket.
Install the filter.
Содержание 5906083854217
Страница 27: ...27 RUS 230 50 60 1 5 2 100 2 5 2 IEC 245 4 93 II 2 5 40 OFF ON III IV V...
Страница 28: ...28 RUS VI III ON VII ON VIII IX X OUTPUT OUTPUT OVERLOAD OUTPUT...
Страница 30: ...30 RUS 0 3 10 3 50 6 100 12 300 X X X X X X X X X X...
Страница 31: ...31 RUS XI XI 0 7 0 8 XII XIII III OFF...
Страница 33: ...33 UA 230 50 60 1 5 2 100 2 5 2 IEC 245 4 93 II 2 5 40 OFF ON III IV V...
Страница 34: ...34 UA VI III ON VII ON VIII IX X OUTPUT OUTPUT OVERLOAD OUTPUT OVERLOAD OUTPUT OVERLOAD OVERLOAD 4...
Страница 35: ...35 UA OIL LEVEL XIV DC PROTECTOR OFF ON XV SM ART THROTTLE ON OFF OFF OFF OFF...
Страница 36: ...36 UA 0 3 10 3 50 6 100 12 300 X X X X X X X X X X XI XI 0 7 0 8 XII...
Страница 37: ...37 UA XIII III OFF...
Страница 82: ...82 I N S T R U K C J A O R Y G I N A L N A...
Страница 83: ...83 I N S T R U K C J A O R Y G I N A L N A...
Страница 84: ...84 I N S T R U K C J A O R Y G I N A L N A...