14
GB
O R I G I N A L I N S T R U C T I O N S
PROPERTIES OF THE DEVICE
The power generator is an electric and mechanical device transforming mechanical energy into electric energy. The power gen-
erator consists of the matching internal-combustion engine and a current generator. A correct, reliable and safe functioning of the
device depends on proper its operation, and therefore:
Before you commence work with the device, read the whole manual and keep it.
The supplier shall not be held responsible for any damage to inobservance of the safety regulations and the recommendations
indicated in this manual.
EQUIPMENT
The generator is sold complete and does not require assembly. The engine of the generator contains the quantity of oil necessary
only for the purpose of maintenance of the engine.
NOTE!
Before the first start of the device, it is required to fill the oil tank. A spark plug wrench is provided along with the generator.
TECHNICAL PARAMETERS
Type of generator
YT-85421
YT-85422
Parameter
Unit of measurement
Value
CURRENT GENERATOR
Nominal voltage
[V]
A.C. 230
A.C. 230
Nominal frequency
[Hz]
50
50
COP nominal power of the generator
[W]
900
1600
Power coefficient
1,0
1,0
Nominal current (AC)
[A]
3,91
6,96
Maximum rotation
[min
-1
]
5500
4500
Electric insulation class
I
I
Housing protection grade (IP)
IP23
IP23
Efficiency class
G1
G1
Maximum rotation
[V]
D.C. 12
D.C. 12
Nominal current (D.C.)
[A]
7,5
7,5
MECHANICAL MOTOR
Type
144F
158F
Number of cylinders
1
1
Number of strokes
4
4
Kind of fuel
Unleaded petrol
Unleaded petrol
Kind of oil
[SAE]
10W-30
10W-30
Consumption of fuel (at the load of 75%)
[l/h]
0,744
1,13
Engine capacity
[cm
3
]
53,5
105,68
Maximum power
[kW]
1,3
2,2
Maximum rotation
[min
-1
]
5500
4500
Cooling
Air cooling
Air cooling
Compression ratio
8:1
8,5:1
Fuel tank capacity
[l]
2,7
3,6
Type of spark plug
A7RTC
A7RTC
DEVICE
External dimensions (length x width x height)
[mm]
465 x 285 x 425
531 x 310 x 440
Weight
[kg]
15
22
Working temperature range
[
O
C]
0
÷
+40
0
÷
+40
Maximum working height
[m above sea level]
1000
1000
Noise level
Acoustic pressure L
pA
±K
[dB(A)]
68,45±3,0
67,06±3,0
Acoustic power L
wA
±K
[dB(A)]
91,68±3,0
88,21±3,0
ADDITIONAL SAFETY INSTRUCTIONS
The generator must be placed upon a flat, even, hard and stable surface. It is necessary to provide at least one meter of free
space around a functioning generator.
It is prohibited to exceed the maximum rotation of the engine. Excessive rotational power of the engine may damage the generator
Содержание 5906083854217
Страница 27: ...27 RUS 230 50 60 1 5 2 100 2 5 2 IEC 245 4 93 II 2 5 40 OFF ON III IV V...
Страница 28: ...28 RUS VI III ON VII ON VIII IX X OUTPUT OUTPUT OVERLOAD OUTPUT...
Страница 30: ...30 RUS 0 3 10 3 50 6 100 12 300 X X X X X X X X X X...
Страница 31: ...31 RUS XI XI 0 7 0 8 XII XIII III OFF...
Страница 33: ...33 UA 230 50 60 1 5 2 100 2 5 2 IEC 245 4 93 II 2 5 40 OFF ON III IV V...
Страница 34: ...34 UA VI III ON VII ON VIII IX X OUTPUT OUTPUT OVERLOAD OUTPUT OVERLOAD OUTPUT OVERLOAD OVERLOAD 4...
Страница 35: ...35 UA OIL LEVEL XIV DC PROTECTOR OFF ON XV SM ART THROTTLE ON OFF OFF OFF OFF...
Страница 36: ...36 UA 0 3 10 3 50 6 100 12 300 X X X X X X X X X X XI XI 0 7 0 8 XII...
Страница 37: ...37 UA XIII III OFF...
Страница 82: ...82 I N S T R U K C J A O R Y G I N A L N A...
Страница 83: ...83 I N S T R U K C J A O R Y G I N A L N A...
Страница 84: ...84 I N S T R U K C J A O R Y G I N A L N A...