5
SETTING OPERATION CONDITIONS
53
5.5
PROGRAMMING MODE
The constants of the VS
−
616G5 are composed of group symbols, function Nos. and serial Nos. for
each function item as shown below. Use
or
key to change the group, function or name
display and select one by [DATA/ENTER] key. For details of the constants, refer to Table A
−
4
”Constants List” or Descriptive Manual for Constants.
Constant No.
b 1
−
01
Serial No. for each
function item
Function No.
Group symbol
b : Application
−
related constants
C : Accel/decel time setting constants
d : Frequency reference
−
related constants
E : Motor
−
related constants
F : Option
−
related constants
H : Control circuit terminal
−
related constants
L : Protection
−
related constants
o : Operator
−
related constants
Constants to be set/read by digital operator can be selected by setting the access level (constant
A1
−
01) as described below.
Table 22 Constant Access Level
A1
−
01
Name
Description
0
Exclusive for monitoring
Constants can be set/read in operation mode or initialize mode.
Constants cannot be set/read in programming mode or modified
constants mode.
1
User selected constants
⋅
Up to 32 constants to be set/read by digital operator can be selected.
⋅
When A1
−
01=01 is selected, constants specified by A2
−
01 to 32 can
be set/read by digital operator. Set the constant numbers in A2
−
01 to
32.
⋅
When constant numbers are not set in A2
−
01 to 32, user selected
constants by A1
−
01 cannot be set/read.
2
QUICK
−
START
Constants required for quick
−
start operation are set/read. For details,
refer to Descriptive Manual for Constants.
3
BASIC
Constants required for basic operation are set/read. For details, refer to
Descriptive Manual for Constants.
4
ADVANCED
Constants required for advanced operation are set/read. For details,
refer to Descriptive Manual for Constants.