7.3 Activate OPC UA functionality
For your CPU can process a
OPC UA
project, you have to activate the
OPC UA
function-
ality.
1.
Insert a memory card from VIPA (VSD, VSC) into your CPU. Please note that you
must always use a VSC card suitable for your CPU.
storage media - VSD, VSC’ page 111
2.
Turn on the CPU, to activate the
OPC UA
functionality, you have to establish an
Overall reset
.
ð
As long as the memory card is inserted, the
OPC UA
functionality remains acti-
vated even after a power cycle. When the project is transferred from the
OPC
UA Configurator
, the
OPC UA
project is automatically transferred to the inserted
memory card.
Please regard that the memory card must remain plugged when
you’ve executed activated the OPC UA functionality. Otherwise
the SF LED is on and the OPC UA functionality is deactivated
after 72 hours. As long as an activated memory card is not
inserted, the SF LED is on and the "TrialTime" timer counts
from 72 hours down to 0. After that the OPC UA functionality is
de-activated. By inserting the memory card, the LED goes off
and the CPU runs again without restrictions.
Please note that the use of a OPC UA project, depending on
the scope of the OPC UA project and the PLC project, can influ-
ence the performance and thus the response time of your appli-
cation.
7.4 Usage in VIPA SPEED7 Studio
n
VIPA
SPEED7 Studio
from Version V1.8.6
–
The functionality for the
OPC UA
configuration is integrated in the
SPEED7
Studio
. For more information, see the according online help.
7.5 Usage in Siemens SIMATIC Manager
Siemens SIMATIC Manager from V5.5 and VIPA
SPEED7 Studio
from V1.8.6
n
The
OPC UA
configuration happens by the external
OPC UA Configurator
from VIPA.
n
The
OPC UA Configurator
is the
SPEED7 Studio
reduced to
OPC UA
functionality.
n
The
OPC UA Configurator
can be registered in the Siemens SIMATIC Manager by
means of the
SPEED7 Tools Integration
.
n
The
OPC UA Configurator
is to be called from the Siemens SIMATIC Manager after
project creation and online configuration.
n
The
OPC UA Configurator
automatically imports the data for the
OPC UA
configura-
tion from the project data of the Siemens SIMATIC Manager.
n
The
OPC UA
configuration is transferred online from the
OPC UA Configurator
. The
OPC UA Configurator
automatically imports the data for the
OPC UA
configuration
from the project data of the Siemens SIMATIC Manager.
Proceeding
Precondition
Precondition
VIPA System SLIO
Deployment OPC UA
Usage in Siemens SIMATIC Manager
HB300 | CPU | 013-CCF0R00 | en | 19-30
192