1
Counter value
=
comparison value
®
comparison bit
is set and
hysteresis
activated
2
Leave
hysteresis
range
®
comparison bit
is reset and
Counter value
<
comparison
value
3
Counter value
=
comparison value
®
comparison bit
is set and
hysteresis
activated
4
Comparison bit
is reset for leaving
hysteresis
range and counter value
>
comparison
value
5
Counter value
=
comparison value
®
comparison bit
is set and
hysteresis
activated
6
Counter value
=
comparison value
and
hysteresis
active
®
comparison bit
remains
set
7
Leave
hysteresis
range and
counter value
>
comparison value
®
comparison bit
is
reset
With reaching the comparison condition the
hysteresis
gets active. At active
hysteresis
the comparison result remains unchanged until the
counter value
leaves the set
hyste-
resis
range. After leaving the
hysteresis
range a new
hysteresis
is only activated with
again reaching the comparison conditions.
4.6 Diagnostic and interrupt
Event
Process interrupt
Diagnostics
interrupt
parameterizable
Overflow
X
-
X
Underflow
X
-
X
Comparison value
X
-
X
End value
X
-
X
Diagnostics buffer overflow
-
X
-
Process interrupt lost
-
X
-
So you may react to asynchronous events, there is the possibility to activate a process
interrupt. A process interrupt interrupts the linear program sequence and jumps
depending on the master system to a corresponding Interrupt routine. Here you can react
to the process interrupt accordingly.
With CANopen the process interrupt data a transferred via an emergency telegram.
Operating with CPU, PROFIBUS and PROFINET the process interrupt data were trans-
ferred via diagnostics telegram.
SX - Subindex for access via EtherCAT with Index 5000h
Effect at counter value =
comparison value
Overview
Process interrupt
VIPA System SLIO
Deployment
Diagnostic and interrupt
HB300 | FM | 050-1BB00 | en | 19-38
55