4 Inputs and Outputs
4.2.2 400 V SERVOPACKS
22
4.2.2
400 V SERVOPACKS
Default settings are provided in parentheses
.
Signal
Pin
No.
Name
Function
ALM+
3
Servo Alarm Output
Turns OFF (opens) when an error is detected.
ALM-
4
/SO1+
(/BK+)
1
General-purpose
Digital Output 1
(Brake Output)
You can allocate the output signal to use with a parame-
ter.
(Controls the brake. The brake is released when the sig-
nal turns ON (closes).)
/SO1-
(/BK-)
2
/SO2+
23
General-purpose
Digital Output 2
Used for general-purpose outputs.
Set the parameters to allocate functions.
/SO2-
24
/SO3+
25
General-purpose
Digital Output 3
/SO3-
26
/SO4+
27
General-purpose
Digital Output 4
/SO4-
28
/SO5+
29
General-purpose
Digital Output 5
/SO5-
30
PAO
17
Encoder Divided
Pulse Output, Phase
A
Output the encoder divided pulse output signals with a
90° phase differential.
/PAO
18
PBO
19
Encoder Divided
Pulse Output, Phase
B
/PBO
20
SG
16
Signal ground
This is the 0-V signal for the control circuits.