4 Inputs and Outputs
4.2.1 200 V SERVOPACKS
21
4.2 Output Signals
4.2.1
200 V SERVOPACKS
Default settings are provided in parentheses
.
Signal
Pin
No.
Name
Function
ALM+
3
Servo Alarm Output
Turns OFF (opens) when an error is detected.
ALM-
4
/SO1+
(/BK+)
1
General-purpose Digi-
tal Output 1 (Brake
Output)
You can allocate the output signal to use with a parameter.
(Controls the brake. The brake is released when the signal
turns ON (closes).)
/SO1-
(/BK-)
2
/SO2+
23
General-purpose Digi-
tal Output 2
Used for general-purpose outputs.
Set the parameters to allocate functions.
/SO2-
24
/SO3+
25
General-purpose Digi-
tal Output 3
/SO3-
26
PAO
17
Encoder Divided
Pulse Output, Phase
A
Output the encoder divided pulse output signals with a 90°
phase differential.
/PAO
18
PBO
19
Encoder Divided
Pulse Output, Phase
B
/PBO
20
PCO
21
Encoder Divided
Pulse Output, Phase
C
Outputs the origin signal once every encoder rotation.
/PCO
22
SG
16
Signal ground
This is the 0-V signal for the control circuits.
FG
Shell Frame
ground
Connected to the frame ground if the shield of the I/O Signal
Cable is connected to the connector shell.