8.10 Vibration Suppression
8.10.2 Preparations
8-56
8.10.2
Preparations
Check the following settings before you execute vibration suppression.
•
Position control must be used.
•
The tuning-less function must be disabled (Pn170 = n.
0).
•
The test without a motor function must be disabled (Pn00C = n.
0).
•
The parameters must not be write prohibited.
8.10.3
Applicable Tools
The following table lists the tools that you can use to perform vibration suppression and the
applicable tool functions.
8.10.4
Operating Procedure
Use the following procedure to perform vibration suppression.
1.
Perform steps 1 to 7 of the procedure for custom tuning. Refer to the following section
for details.
2.
Click the
Vib Suppress
Button.
Tool
Function
Operating Procedure Reference
Digital Operator
Fn205
Σ
-7-Series Digital Operator Operating Man-
ual (Manual No.: SIEP S800001 33)
S
Tuning - Tuning