16.1 List of Parameters
16.1.2 List of Parameters
16-17
16
Parameter and Object Lists
Pn310
(2310 hex)
2
Vibration Detection
Selections
0000 hex to
0002 hex
−
0000
hex
All
Immedi-
ately
Setup
Pn311
(2311 hex)
2
Vibration Detection Sen-
sitivity
50 to 500
1%
100
All
Immedi-
ately
Tuning
Pn312
(2312 hex)
2
Vibration Detection
Level
0 to 5,000
1 min
-1
50
Rotary
Immedi-
ately
Tuning
Pn316
(2316 hex)
2
Maximum Motor Speed
0 to 65,535
1 min
-1
10000
Rotary
After
restart
Setup
Pn324
(2324 hex)
2
Moment of Inertia Cal-
culation Starting Level
0 to 20,000
1%
300
All
Immedi-
ately
Setup
Pn383
(2383 hex)
2
Jogging Speed
0 to 10,000
1 mm/s
50
Linear
Immedi-
ately
Setup
Pn384
(2384 hex)
2
Vibration Detection
Level
0 to 5,000
1 mm/s
10
Linear
Immedi-
ately
Tuning
Pn385
(2385 hex)
2
Maximum Motor Speed
1 to 100
100
mm/s
50
Linear
After
restart
Setup
Pn401
(2401 hex)
2
First Stage First Torque
Reference Filter Time
Constant
0 to 65,535
0.01 ms
100
All
Immedi-
ately
Tuning
Pn402
(2402 hex)
2
Forward Torque Limit
0 to 800
1%
*1
800
Rotary
Immedi-
ately
Setup
Pn403
(2403 hex)
2
Reverse Torque Limit
0 to 800
1%
*1
800
Rotary
Immedi-
ately
Setup
Pn404
(2404 hex)
2
Forward External Torque
Limit
0 to 800
1%
*1
100
All
Immedi-
ately
Setup
Pn405
(2405 hex)
2
Reverse External Torque
Limit
0 to 800
1%
*1
100
All
Immedi-
ately
Setup
Pn406
(2406 hex)
2
Emergency Stop Torque
0 to 800
1%
*1
800
All
Immedi-
ately
Setup
Pn407
(2407 hex)
2
Speed Limit during
Torque Control
0 to 10,000
1 min
-1
10000
Rotary
Immedi-
ately
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Vibration Detection Selection
0
Do not detect vibration.
1
Output a warning (A.911) if vibration is detected.
2
Output an alarm (A.520) if vibration is detected.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X