15.4 Troubleshooting Based on the Operation and Conditions of the Servomotor
15-58
Absolute
Encoder
Position
Deviation
Error (The
position
that was
saved in the
host con-
troller when
the power
was turned
OFF is dif-
ferent from
the posi-
tion when
the power
was next
turned ON.)
The encoder was subjected
to excessive vibration or
shock.
Turn OFF the Servo Sys-
tem. Check to see if
vibration from the
machine occurred.
Check the Servomotor
installation (mounting sur-
face precision, securing
state, and alignment).
Check the linear encoder
installation (mounting sur-
face precision and secur-
ing method).
Reduce machine vibra-
tion. Improve the
mounting state of the
Servomotor or linear
encoder.
–
A failure occurred in the
encoder.
–
Turn OFF the Servo
System. Replace the
Servomotor or linear
encoder.
–
A failure occurred in the SER-
VOPACK.
–
Turn OFF the Servo
System. Replace the
SERVOPACK.
–
Host controller multiturn data
or absolute encoder position
data reading error
Check the error detec-
tion section of the host
controller.
Correct the error detec-
tion section of the host
controller.
–
Check to see if the host
controller is executing
data parity checks.
Perform parity checks
for the multiturn data or
absolute encoder posi-
tion data.
–
Check for noise interfer-
ence in the cable
between the SERVO-
PACK and the host con-
troller.
Implement counter-
measures against noise
and then perform parity
checks again for the
multiturn data or abso-
lute encoder position
data.
–
Continued on next page.
Continued from previous page.
Problem
Possible Cause
Confirmation
Correction
Reference