16.1 List of Parameters
16.1.2 List of Parameters
16-24
Pn510
(2510 hex)
2
Output Signal Selec-
tions 3
0000 hex to
0666 hex
–
0000
hex
All
After
restart
Setup
–
Pn511
(2511 hex)
2
Input Signal Selections
5
0000 hex to
FFFF hex
–
6543
hex
All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
/NEAR (Near Output) Signal Allocation
Reference
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4
Output the signal from the CN1-27 or CN1-28 output terminal.
5
Output the signal from the CN1-29 or CN1-30 output terminal.
6
Reserved setting (Do not use.)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
/Probe1 (Probe 1 Latch Input) Signal Allocation
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
The signal is always inactive.
8
The signal is always inactive.
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
n.
X
/Probe2 (Probe 2 Latch Input) Signal Allocation
0 to F
The allocations are the same as the /Probe1 (Probe 1 Latch Input) signal allo-
cations.
n.X
/Home (Home Switch Input) Signal Allocation
0 to F
The allocations are the same as the /Probe1 (Probe 1 Latch Input) signal allo-
cations.