11 SERVOPACK with Semi-closed Loop Control for Linear Motors
11-2
11.1
Magnetic Pole
For driving linear motors, the magnetic pole should be coordinated. The parameters in the following table are
used for that.
Parameter Setting
Note: In case the hall sensor is not available refer to chapter 11-4.
Parameter
Function
Default Value
When enabled
No.
Dig.
Pn080
Application Function Select Switch 80
-
-
0
Hall Sensor Selection
0
After restart
0
Enables hall sensor
1
Disables hall sensor
Pn081
Application Function Select Switch 81
-
-
3
Hall Sensor Signal Inversion
0
After restart
0
Does not inverse the signals (Pos-Logic)
1
Inverses the signals (Neg-Logic)
Positive logic
Pn080.0 = 0
Pn081.3 = 0
Pn080.0 = 0
Pn081.3 = 1
Pn080.0 = 1
Pn081.3 = 0
Negative logic
Available
Not available
Hall Sensor
Hall Sensor Signal
Parameter Setting