10.3 Pole Detection Functionality
10-5
10
SER
VOP
ACK with Semi-closed Loop Control for Rotary Motors
After the function has been completed the motor power will turn OFF and the Servo Ready signal will turn
ON. Then the function cannot be executed even if the /P-DET signal is turned ON and OFF. Then the control
power is restored, the function must be executed again.
Utility Function: Pole Detection (Fn080)
This utility function is executed using Panel operator, Digital operator and S.
(3) Execution of the Function with MECHATROLINK and Network Option Model
Servo ON Command
Utility Function: Pole Detection (Fn080)
This utility function is executed using Panel operator, Digital operator and S.
(4) Related Parameters
Type
Name
Connector Pin No.
Setting
Description
Input
/S-ON
CN1-40
[Factory setting]
ON
Motor power is ON.
Motor will be ready for operation (/S-RDY signal is
ON).
OFF
Motor power is OFF.
/P-DET
Must be allocated
ON
The function is executed only once then the signal
turns ON for the first time.
OFF
-
Type
Name
Description
Servo ON
Incremental Encoder
The function is executed only once when the command is sent. Then,
motor will be ready for operation.
Absolute Encoder
In the Pn587.0 = 1 setting, the function is executed only once when
the command is sent. Then, motor will be ready for operation.
Servo OFF
Motor power is OFF.
Parameter
Function
Default Value
When enabled
No.
Dig.
Pn481
Polarity Detection Speed Loop Gain [0.1 Hz]
40.0
Immediately
Pn482
Polarity Detection Speed Loop Integral Time [0.01 msec]
30.00
Immediately
Pn486
Polarity Detection Command Accel/Decel Time [msec]
25
Immediately
Pn487
Polarity Detection Constant Speed Time [msec]
0
Immediately
Pn488
Polarity Detection Command Waiting Time [msec]
100
Immediately
Pn490
Polarity Detection Load Level [%]
100
Immediately
Pn493
Polarity Detection Command Speed [min
-1
]
50
Immediately
Pn494
Polarity Detection Range [0.001 rev]
0.250
Immediately
Pn495
Polarity Detection Confirmation Torque Command [%]
100
Immediately
Pn498
Polarity Detection Allowable Error Range [deg.]
10
Immediately
Pn587
Polarity Detection for Absolute Scale Selection
-
-
0
0
Does not detect polarity
0
Immediately
1