8 Set-up Procedure for Semi-closed Loop Control
8.2.1 Feedback Option Module Set-up
8-8
Even if a feedback option card is connected, the following message will appear if the option card contains
no motor data or encoder data.
• When using S
Start S. Click
Monitor
in the main menu and then click
Product Information
.
Note: The linear scale pitch can be checked by using the monitor mode parameters Un084 (Linear Scale Pitch) and Un085
(Linear Scale Pitch Index).
• Example
When Un084 = 800, and Un085 = 6
Linear scale pitch = Un084 × 10
Un085
[pm] = 800 × 10
6
[pm] = 800 [µm]
B B - FBOpMotID -