Derating Specifications
If you use the SERVOPACK at a surrounding air temperature of 55
C to 60
C
or at an altitude of 1,000 m to 2,000 m, you must apply the derating rates given
in the following graphs.
Note: If you combine a
-7-Series SERVOPACK with a
-V-Series Option Mod-
ule, you cannot exceed a surrounding air temperature of 55°C or an altitude
of 1,000 m even with derating.