4.2 CPU Module Specifications
4.2.7 System Register Specifications
4-19
4
S
pecification
s
Program Error
Drawing Number
SW00056
FFFF hex
Ladder program parent drawing
8000 hex
Ladder program function
00 hex
Ladder program child drawing (
hex:
Child drawing No.)
hex
Ladder program grandchild drawing
F
hex
Motion program or sequence program
(
hex: Program No.)
Drawing Type of
Calling Program
SW00057
Type of the calling drawing in which the error occurred
0001 hex
DWG.A
0002 hex
DWG.I
0003 hex
DWG.H
0005 hex
DWG.L
0008 hex
Function
000F hex
Motion program/sequence program
Drawing No. of
Calling Program
SW00058
Number of the calling drawing in which the error occurred
FFFF hex
Parent drawing
8000 hex
Function
00 hex
Child drawing (
hex: Child drawing No.)
xxyy hex
Grandchild drawing (xx hex: Child drawing
No., yy hex: Grandchild drawing No.)
Drawing Step No. in
Calling Program
SW00059
Step Number in the Calling Drawing in Which the Error Occurred
This is set to 0 if the error occurs in the parent drawing.
Error Data
SW00060 and
SW00061
Reserved for system.
SW00062 to
SW00065
Name of task that caused the error
SW00066 and
SW00067
Reserved for system.
SW00068
Year When Error Occurred
SW00069
Month When Error Occurred
SW00070
Day of Week When Error Occurred
SW00071
Day When Error Occurred
SW00072
Hour When Error Occurred
SW00073
Minutes When Error Occurred
SW00074
Seconds When Error Occurred
SW00075
Milliseconds When Error Occurred
SW00076
xyzz hex
Slot Where the Module Synchronization
Error Was Detected (x: Rack number from 1
to 7, y: module number from 1 to 4, zz: slot
number from 01 to 09)
SW00077 to
SW00079
Reserved for system.
Continued on next page.
Continued from previous page.
Name
Register
Address
Contents
hex
Grandchild drawing number
Child drawing number