Fieldbus PCI-Card
Card
No:
Indication
State
Meaning
3
Master status
Green
Operate Mode
Green, flashing
Clear Mode
Red
Stop Mode
Off
Offline
4
Token hold
Green
Master has the token
Off
Master does not have the token
5
Database Status
Green
Database OK
Green, flashing
Database download in progress
Red
Database invalid
Off
No database downloaded
6
Communication status
Green
Data exchange with all configured
slaves
Green, flashing
Data exchange with at least one
configured slave
Red
Bus control error (Possible short
circuit or configuration error)
Off
No data exchange with any off the
configurated slaves
Fieldbus interface
A
B
Fig. 21 D-sub layout
A. D-sub, male layout
B. D-sub, female layout
Pin
Signal
Housing
Cable shield
1
-
2
-
3
B-Line
4
RTS
5
GND_BUS
6
+5V BUS (output)
7
-
8
A-Line
9
-