Fieldbus PCI-Card
Card
No:
Indication
State
Meaning
4
Auto prog, slave 0 exist
Off
No error, no slave 0,
autoprogrammming not possible
8Hz Green
Auto programming possible
1Hz Green
Slave address 0 exist
Red
Periphery error
8Hz Red
Perophery error, auto-programming
possible
1Hz Red
Periphery error, slave address 0 exist
5
Network status
Off
No power or not initialized
Green, flashing
online according to configuration
Green
Online, but no connections
established
Red
Offline
6
Module status
Off
No power or not initialized
Green, flashing
Protected mode
Green
Configuration mode
Red
Power fail bus
9.2.2
Connectors
1
2
3
Fig. 27 Connector PCI AS-interface Master
No:
Signal
1
AS-Int
2
-
3
AS-Interface -
9.2.3
Rectifying of interruption
Since there are possibilities of AS-interface being affected by interruption, a ferrite clip should be
attached to its bus cable according to Fig. 28
Ferrite clip on cable
.
Fig. 28 Ferrite clip on cable