9 Description of Units and Circuit Boards
9-5
168283-1CD
168283-1CD
Hardware Installation &
Software Upgrade
Installation of Safety Plug
The manipulator must be surrounded by a safeguarding and a door
protected by an interlock function. The door must be opened by the
technician to enter and the interlock function stops the robot operation
when the door is open. The safety plug input signal is connected to the
interlock signal from the gate.
If the servo power is ON when the interlock signal is input, the servo
power turns OFF. The servo power cannot be turned ON while the
interlock signal is input. However, the servo power does not turn OFF
when the door is opened only during the teach mode. In this case, the
servo power can be turned ON while the interlock signal is input.
Safety Plug
Emergency
Stop
Taked Plug
Safeguarding
Safeguarding
Manipulator
Working Area
MLX200
Servo ON Lamp (Option)