YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
57
Parameter
Operator Display
Description
Value Range
Default Value
S7-17
ShftInp FltrTme2
Defines the, usually larger, filter time 2 for the shaft error input value which
becomes effective below the
Shaft Filter Switch Level [S7-18]
.
0.00 ... 50.00 s
0.00 s
S7-18
ShftFilSwitchLvl
Sets the level below which
Shaft Filter Time 2 [S7-17]
is applied. This
functions helps to rule-out swings of the lift car when running into level
position.
0.00 ... 10.00 Hz
2.00 Hz
S7-30
Shaft Pos Trim
Trims the final shaft position by some mm by adding this value to the actual
lift car position feedback.
-10 to 10 mm
(-0.39 .. 0.39 in)
0 mm
(0.00 in)
S7-31
Min. Prol. Jump
Distance prolongations are only accepted when they exceed
S7-31
value.
Note:
This parameter is not used in CAN-Lift.
0 to 50 mm
(0.00 .. 2.00 in)
30 mm
(1.18 in)
S7-32
ShD Auto-Tuning
Enables Sheave Diameter Auto-Tuning. After every profile positioning drive,
o1-20
is adapted stepwise minimizing
U4-53
/
U4-54
.
The parameter is automatically reset after 6 travels. To insure proper tuning,
always drive the longest distance occurring in the lift installation.
0 - 1
0
S7-33
BrakDistFactor
Increases the current braking distance and
‘
I7
’
telegram reply for the braking
distance. This forces a lift controller to perform distance prolongation earlier
(safety margin).
Note:
This parameter is not used in CAN-Lift.
0.0 - 20.0%
0.0%
S7-34
RescPRMSetActive
Enables evacuation speed
d1-25
to be used as limiting V4 DCP speed.
0 : Disabled
1 : Enabled
Although
V4 [d1-01]
might be commanded by the controller,
d1-25
is used as
the limiting DCP speed. In that case,
V4
is displayed in the FREF menu.
Note:
This parameter is not used in CAN-Lift.
0 - 1
0
S7-40
DCPInt I/F Enabl
Selects the controller distance change method.
0 : Prolongation (for MPK400c, bp30x)
1 : Shortening (for LiSA20, SLC4-20)
If
S7-40 = 0
, also set
S7-44 = 0
.
0 - 1
H5-13 = 4:
1
H5-13 ≠ 4:
0
S7-41
I/F LowMarginMin
Defines the interface
’
s lower margin minimum value.
20 to
S7-42
mm
(0.79 ..
S7-42
in)
120 mm
(4.724 in)
S7-42
I/F LowMarginMax
Defines the interface
’
s lower margin maximum value.
S7-41
to 500 mm
(
S7-41
.. 19.69 in)
150 mm
(5.91 in)
S7-43
Interface Offset
Defines the Interface Offset. It includes the interface low the I/F
jump height.
30 to 900 mm
(1.18 .. 35.43 in)
400 mm
(15.75 in)
S7-44
BrakDistOffset
Defines the total Braking Distance Offset. The offset is added to the true
Braking Distance. The value with offset is communicated to the lift controller
(to allow enough margin for distance shortening controllers). It is also added to
‘
I7
’
telegram reply.
0 to 1000 mm
(0 .. 39.37 in)
500 mm
(19.69 in)
S7-50
Mfctr Code ZA En
Switches the drive manufacturer code within
‘
I0
’
command to
‘
ZA
’
instead of
‘
YE
’
which is necessary for controllers not (yet) supporting Yaskawa drives.
0 : YE
1 : ZA
Power needs to be cycled to activate the changed string
0 - 1
0
*1
Values not in parentheses apply when
o1-12 = 0
. Values in parentheses apply when
o1-12 = 1
.
■
Added Standard Parameter Scroll Items
Parameter
Operator Display
Description
Value Range
Default Value
b1-01
Ref Source 1
Speed Reference Selection 1
0 : Operator Keypad
1 : Terminals
2 : Memobus/Modbus Communications
3 : Option Card
6 : DCP/CANopen-Lift
0 - 3, 6
H5-13 = 1:
0
H5-13 ≠ 1:
6
b1-02
Run Source 1
Up / Down Command Selection
0 : Operator Keypad
1 : Control Circuit Terminal
2 : Memobus/Modbus Communications
3 : Option Card
6 : DCP/CANopen-Lift
0 - 3, 6
H5-13 = 1:
1
H5-13 ≠ 1:
6
■
Modified Standard Parameters
Only modified parameters are listed in this table. If parameter
H5-13 = 3 or 4 or 5
, the following changes apply:
EN
Содержание L1000A CIMR-LC F Series
Страница 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 97: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 97 15 Appendix EN...
Страница 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Страница 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Страница 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...