YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
63
Added DOMF
H2-xx Setting
(Hex)
Operator Display
Description
Available in Control Method
70 (170)
In Position
The lift car has reached the commanded target position within
S7-01
bandwidth for a minimum continuous time of
S7-02
CLV, PMCLV
■
Changes of Standard Analog Input Multi-Functions (AIMF)
AIMF Availability by H5-13 Setting
H3-xx Setting
(Hex)
Function Name
H5-13 = 0, 1
H5-13 = 3, 4, 5
0
Speed Reference Bias
Available
Not available
2
Auxiliary Speed Reference 1
3
Auxiliary Speed Reference 2
When
H5-13 ≥ 3
, value and default of parameter
H3-02
are set to
0x1F [not used]
.
When
H5-13 ≥ 3
, default of parameter
H3-10
is set to
0x1F [not used]
.
■
Added Faults and Modified Errors
Added DCP Faults
Fault
Fault Code
(Hex)
Fault Display
Description
Cause
Countermeasure
DCE1
61
DCP CRC Error
Drive Control Position Cyclic Redundancy Check Error
A CRC8 check failed 10 times consecutively during
RUN.
EMC, bad
serial link
Shield serial link. Check serial RS-485
connection (Termination Resistance
switched by S2).
DCE2
62
DCP Init Error
Drive Control Position Initialization Error
A Run command was given although no valid
initialization command ('I','1') was received.
EMC, bad
serial link
Check if lift controller sends valid
initialization command.
DOE1
63
DCP OPE
Drive Control Position Operation Error
A Run command was given although the inverter was in
Alarm state.
Alarm
Remove alarm condition. Lift controller
must not give Run during Alarm state.
Modified oPE Errors
Error
Description
Cause
Countermeasure
oPE18
DCP3, DCP4, CANopen Lift:
If b1-01 is set to 6 "DCP" and b1-02 is set ≠ 6 or vice versa, oPE18 is shown.
b1-01 = 6 AND
b1-02 ≠ 6
b1-02 ≠ 6 AND
b1-02 = 6
Set b1-01 = 6 AND b1-02 = 6
Modifications of FREF Menu Texts
Menu Text
Display
Displayed
when
Description
Active Speed (Command by Lift
Controller
Message Text
ME-01
V0
FreqRef(DCP-V0)
b1-01 = 6
DCP sequence is activated (also used for CANopen Lift)
VN: Releveling speed
VI: Inspection speed
VF: Fast Start speed (0Hz)
V1
FreqRef(DCP-V1)
V2
FreqRef(DCP-V2)
V3
FreqRef(DCP-V3)
V4
FreqRef(DCP-V4)
V5
FreqRef(DCP-V5)
V6
FreqRef(DCP-V6)
V7
FreqRef(DCP-V7)
VN
FreqRef(DCP-VN)
VI
FreqRef(DCP-VI)
VF
FreqRef(DCP-VF)
undefined
FreqRef(DCP)
ME-01
FreqRef(CANLift)
H5-13 = 5
CANopen Lift uses DCP sequence internally.
Differentiation is done by H5-13.
EN
Содержание L1000A CIMR-LC F Series
Страница 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 97: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 97 15 Appendix EN...
Страница 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Страница 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Страница 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...