3.2 Function Modules
Data Logging
3-75
3
CPU Unit Functionality
12.
Click the
OK
Button.
The Logging Target Dialog Box closes.
13.
Click the
Sampling and trigger
Button in the Logging 1 Dialog Box.
The Sampling and Trigger Dialog Box will be displayed.
Delete
Button
Removes the selected registers from the list of registers to be
logged.
Logging Target
Displays a list of the registers that will be logged. Registers can be
added to this list either by selecting them from the Logging Target
List or by entering them directly.
• Right-click in the Logging Target Area to display a pop-up menu
to edit the registers to be logged.
Insert Row
inserts a blank row.
Delete Row
deletes a row. If a logging target was added, then it
will be deleted.
The following register types can be logged.
• S, M, G, I, O, and D registers
Refer to the following table for the data size for each data type.
Click the
Cancel
Button to return to the Logging 1 Dialog Box without registering the set-
tings.
Continued from previous page.
No.
Item
Description
Information
Information
Data Type
Data Size
B: bit
1 word
W: integer
1 word
L: double-length integer
2 words
Q: quadruple-length integer
4 words
F: single-precision real number
2 words
F: double-precision real number
4 words
Information