Application Selections
6
-
3
Fig 6.1
*K is the coefficient determined by the set value in C6-03.
C6-03
≥
10.0 kHz: K=3
10.0 kHz > C6-03
≥
5.0 kHz: K=2
5.0 kHz > C6-03: K=1
•
To fix the carrier frequency, set C6-03 and C6-04 to the same value, or set C6-05 to 0.
•
If Carrier Frequency Proportional Gain (C6-05) > 6 and C6-03 < C6-04 an OPE11 fault (Data setting
error) will occur.
Carrier Frequency
Output frequency
E1-04
Max. Output Frequency
Output frequency x C6-05
x K*
C6-03
C6-04