![YASKAWA CIMR-SSA Series Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/yaskawa/cimr-ssa-series/cimr-ssa-series_instruction-manual_3629091074.webp)
APPENDIX 2 DIMENSIONS (mm)
75
Table A
−
3 VS-686SS5 Dimensions (mm) and Approx. Mass (kg)
Max.
Open Chassis Type (IP00)
Enclosed Wall-mounted Type (NEMA1)
Volt-
age
Class
Max.
Applicable
Motor
Output
[kW]
W
H
D
W1
H1
H2
Approx.
Mass
W
H
D
W1
H1
H2
Approx.
Mass
Mount-
ing
Holes d
*
1
DC
Reac-
tor
*1
0.4
0.75
140
280
160
126
266
7.0
3
140
280
160
126
266
7.0
3
M5
1.5
2.2
140
280
180
126
266
7 0
4 5
140
280
180
126
266
7 0
4 5
M5
3.7
140
280
180
126
266
7.0
4.5
140
280
180
126
266
7.0
4.5
M5
Option
5.5
200
300
205
186
285
8 0
5.5
200
300
205
186
285
8 0
5.5
M6
p
7.5
200
300
205
186
285
8.0
6
200
300
205
186
285
8.0
6
M6
200V
11
250
380
225
236
365
7 5
11
250
380
225
236
365
7.5
11
M6
200V
Class
15
250
380
225
236
365
7.5
11
250
400
225
236
365
27.5
11
M6
18.5
325
450
285
275
435
7 5
28
330
610
285
275
435
87.5
32
M6
22
325
450
285
275
435
7.5
28
330
675
285
275
435
152.5
32
M6
30
425
675
350
320
650
12 5
61
430
985
350
320
650
212 5
67
M10
B ilt
37
425
675
350
320
650
12.5
62
430
985
350
320
650
212.5
68
M10
Built-
in
45
475
800
350
370
775
12 5
80
480
1110
350
370
775
212 5
87
M10
in
55
475
800
350
370
775
12.5
80
480
1110
350
370
775
212.5
87
M10
75
575
925
400
445
895
15.0
135
580
1290
400
445
895
270
145
M12
0.4
140
280
160
126
266
7 0
3
140
280
160
126
266
7 0
3
M5
0.75
140
280
160
126
266
7.0
3
140
280
160
126
266
7.0
3
M5
1.5
4
4
2.2
140
280
180
126
266
7.0
4 5
140
280
180
126
266
7.0
4 5
M5
3.7
4.5
4.5
Option
5.5
200
300
205
186
285
8 0
6
200
300
205
186
285
8 0
6
M6
p
7.5
200
300
205
186
285
8.0
6
200
300
205
186
285
8.0
6
M6
11
250
380
225
236
365
7 5
11
250
380
225
236
365
7 5
11
M6
15
250
380
225
236
365
7.5
11
250
380
225
236
365
7.5
11
M6
400V
18.5
325
450
285
275
435
7 5
29
330
610
285
275
435
87 5
32
M6
400V
Class
22
325
450
285
275
435
7.5
31
330
610
285
275
435
87.5
34
M6
30
785
87 5
37
325
625
285
275
610
7.5
44
330
785
285
275
610
87.5
48
M6
B ilt
45
850
152.5
Built-
in
55
455
820
350
350
795
12 5
81
460
1130
350
350
795
212 5
87
M10
in
75
455
820
350
350
795
12.5
82
460
1130
350
350
795
212.5
88
M10
110
575
925
375
445
895
15 0
135
580
1290
375
445
895
270
145
M12
160
575
925
400
445
895
15.0
145
580
1290
400
445
895
270
155
M12
220
950
1450
435
*
2
1400
25
360
M12
300
960
1600
455
*
2
1550
25
420
M12
*1
Same for open chassis type and enclosed wall-mounted type.
*2
See page 70 for mounting dimensions.
Note: An attachment is required to mount the cooling fins (fin section) on the outside of the enclo-
sure for 200 V/400 V class inverters of 15 kW or less. Contact your YASKAWA representa-
tive for details. Dimentional drawings for models with externally mounted cooling fins and
other special requirements are also available from your YASKAWA representative.