![YASKAWA CIMR-SSA Series Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/yaskawa/cimr-ssa-series/cimr-ssa-series_instruction-manual_3629091070.webp)
7
TROUBLESHOOTING
71
7.2
MOTOR FAULTS AND CORRECTIVE ACTIONS
If any of the following faults occurs in the motor, check the cause and provide the relevant corrective
action. If these inspections and corrective actions cannot solve the problem, contact your YASKAWA
representative immediately.
Table 32
Motor Faults and Corrective Actions
Fault
Check Point
Corrective Action
Power supply voltage applied to power supply
terminals R, S, T?
⋅
Turn ON power supply.
⋅
Turn OFF power supply, and then ON again.
⋅
Check power supply voltage.
⋅
Make sure terminal screws are tight.
Use rectifier type voltmeter to test. Voltage
output to output terminals U, V, W correct?
Turn OFF power supply, then turn ON again.
Motor locks due to excessive load?
Reduce the load and release the lock.
Motor does not rotate. Fault displayed in digital operator display?
Check Table 29.
FWD or REV run command entered? (only for
REMOTE operation)
Check the wiring.
Speed setting voltage entered?
(Only for REMOTE operation)
⋅
Correct the wiring.
⋅
Check speed setting voltage.
Speed reference selection (b1-01), run com-
mand selection (b1-02) correct?
Input the correct set value.
Motor rotation
reverses
Wiring of terminals U, V, W correct?
Match wiring to the phase order of the motor
leads U, V, W.
reverses.
FWD and REV run signal wirings correct?
Correct the wiring.
Motor rotates, but
variable speed not
Wiring of speed setting circuit correct?
Correct the control circuit wiring.
variable speed not
available.
Load excessively large?
Reduce the load.
Motor ratings (number of poles, voltage)
correct?
Check motor nameplate specifications.
Motor speed too high
or too low.
Accel/decel speed change ratio for gears, etc.
correct?
Check speed changer (gears, etc.)
or too low.
Torque reference saturated?
Check the settings of U1-09 and L7-01 to L7-04.
Maximum speed set value correct?
Check the maximum speed set value (E1-06).
M
d
Load excessively large?
Reduce the load.
Motor speed not
stable during
operation.
Load variation excessively large?
⋅
Reduce the load variation.
⋅
Increase inverter and motor capacity.
operation.
Power supply open-phase?
Check the wiring.
Motor does not rotate
when the power sup-
ply is turned ON with
the operation com-
mand entered.
After switching between LOCAL/REMOTE,
the setting of (b1-06) correct?
Set b1-06=1.