NOTES FOR SAFE OPERATION
7
CAUTION
(Ref. page)
S
Do not connect the other type of motor (i.e. induction motor). The
VS-686SS5 inverter is exclusive-use for SS5 motor drive.
Failure to observe this caution can result in inverter damage.
20
. . . . . . . . . . . . . . . . .
S
Verify that the inverter rated voltage coincides with the AC power supply
voltage.
Failure to observe this caution can result in personal injury or a fire.
20
. . . . . . . . . . .
S
Do not perform a withstand voltage test of the inverter.
It may cause semi-conductor elements to be damaged.
20
. . . . . . . . . . . . . . . . . . . . . .
S
To connect a braking resistor, braking resistor unit or braking unit, follow
the procedures described in APPENDIX 3.
Improper connection may cause a fire. 20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S
Tighten terminal screws to the specified tightening torque.
Failure to observe this caution can result in a fire.
20
. . . . . . . . . . . . . . . . . . . . . . . . . .
S
Never connect the AC main circuit power supply to output terminals U, V
and W.
The inverter will be damaged and invalidate the guarantee.
24
. . . . . . . . . . . . . . . . .
S
(Standard connection)
Be sure to connect the motor leads to the correct output terminals:
Motor lead U to output terminal U,
Motor lead V to output terminal V, and
Motor lead W to output terminal W.
Failure to observe this caution may cause the motor to run unusual way such as in
reverse.
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S
With the standard connection for the output terminals, the motor rotates
counterclockwise as viewed from the load side in a forward operation.
To rotate the motor clockwise in a forward operation, connect the output
terminals as refered in Appendix 6.
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .