Trial Operation
6.4.9 Motor Code Selection (MTR: C1-25)
6
-12
Precautions when Changing the Motor Code
After changing the Motor code, be sure to turn OFF the control power supply. Next, check that the Digital
Operator display is no longer lit, and then turn ON the power supply again. This operation will enable the new
Motor code.
Table 6.4
Motor Codes for Standard Spindle Motors
Voltage
Class
Motor
Inverter
Capacity
Inverter
Capacity
Selection
(C1-56)
Motor Model
Motor
Code
(C1-25)
Motor Max.
Speed
(min
−
1
)
30 min./
Continuous
Rated Out-
put (kW)
Load Fac-
tor Meter
Max. Value
(%)
200 V
Standard
23P7
04
UAASKA-04FZ
j
001
8,000
3.7/2.2
202
25P5
05
UAASKA-06FZ
j
002
8,000
5.5/3.7
178
27P5
06
UAASKA-08FZ
j
003
8,000
7.5/5.5
164
2011
07
UAASKA-11FZ
j
004
6,000
11/7.5
176
2015
08
UAASKA-15FZ
j
005
6,000
15/11
164
2018
09
UAASKA-19FZ
j
006
6,000
18.5/15
148
2022
0A
UAASKA-22FZ
j
007
6,000
22/18.5
143
2030
0B
UAASKJ-30FZ
j
008
4,500
30/22
164
2037
0C
UAASKJ-37FZ
j
009
4,500
37/30
148
Winding
selection
25P5
05
UAASKB-06FZ
j
062
6,000 (1,500)
5.5/3.7
178
selection
27P5
06
UAASKB-08FZ
j
063
6,000 (1,500)
7.5/5.5
164
2011
07
UAASKB-11FZ
j
064
6,000 (1,500)
11/7.5
176
2015
08
UAASKB-15FZ
j
065
4,800 (1,000)
15/11
164
2018
09
UAASKB-19FZ
j
066
4,800 (1,000)
18.5/15
148
2022
0A
UAASKB-22FZ
j
067
4,800 (1,000)
22/18.5
143
2030
0B
UAASKB-30FZ
j
068
4,800 (1,000)
30/20
180
400 V
Standard
45P5
25
UAASKA-06FZ
j
OOE
102
8,000
5.5/3.7
178
47P5
26
UAASKA-08FZ
j
OOE
103
8,000
7.5/5.5
164
4011
27
UAASKA-11FZ
j
OOE
104
6,000
11/7.5
176
4015
28
UAASKA-15FZ
j
OOE
105
6,000
15/11
164
4018
29
UAASKA-19FZ
j
OOE
106
6,000
18.5/15
148
4022
2A
UAASKA-22FZ
j
OOE
107
6,000
22/18.5
143
4030
2B
UAASKJ-30FZ
j
OOE
108
4,500
30/22
164
4037
2C
UAASKJ-37FZ
j
OOE
109
4,500
37/30
148
4045
2D
UAASKJ-45FZ
j
OOE
10A
4,500
45/37
146
Winding
selection
45P5
25
UAASKB-06FZ
j
OOE
162
6,000 (1,500)
5.5/3.7
178
selection
47P5
26
UAASKB-08FZ
j
OOE
163
6,000 (1,500)
7.5/5.5
164
4011
27
UAASKB-11FZ
j
OOE
164
6,000 (1,500)
11/7.5
176
4015
28
UAASKB-15FZ
j
OOE
165
4,800 (1,000)
15/11
164
4018
29
UAASKB-19FZ
j
OOE
166
4,800 (1,000)
18.5/15
148
4022
2A
UAASKB-22FZ
j
OOE
167
4,800 (1,000)
22/18.5
143
4030
2B
UAASKB-30FZ
j
OOE
168
4,800 (1,000)
30/20
180
Note: Values in parentheses are the maximum speed (min
−
1
) of the low-speed windings.
The maximum value of the load factor meter = (30-min rated output x 120%)/(continuous rated output) (%)
6