6
-112
* 1. These are values for a 200-240V Class Drive. Values for a 380-480V Class Drive are double.
* 2. The factory setting will change when the control method is changed. (Open-loop vector control factory settings are given.)
* 3. The contents of parameters E1-11 and E1-12 are ignored when set to 0.00.
* 4. E1-13 is set to the same value as E1-05 by autotuning.
* 5. The setting range is 0 to 66.0 for open-loop vector control 2.
E1-11
Mid. output
frequency 2
Set only to fine-adjust V/f for the output
range. Normally, this setting is not
required.
0.0 to
400.0
*5
0.0Hz
*3
No
A
A
A
A
A
Mid
Frequency B
E1-12
Mid. output
frequency
voltage 2
0.0 to
255.0
*1
0.0 V
*3
No
A
A
A
A
A
Mid Voltage
B
E1-13
Base voltage
0.0 to
255.0
*1
0.0 V
*4
No
A
A
Q
Q
Q
Base Voltage
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2