A05G069A 

unused wires must be cut off or covered the metal ends. 

 

Do not use a inverter as power supply. This cause damage of this product. 

 

Must  drain  the  pipe  before  installation.  Install  pump  to  a    pressured  pipe  is 
extremely high dangerous. It may cause a serious injure of operator. 

 

Do  not  operate  the  pump  in  a  pressure  higher  than  specification  ,  or  fluid  viscosity 
>500 cP or temperature >60

 

This  unit  is  not  suitable  for  all  kind  of  fluid.  Some  solvents,  extreme  acid,  high 
oxidization high temperature or high viscosity fluid may cause malfunction of pump. 

 

Wear a chemical protect mask and gloves before repair or maintenance. 

 

Please  do  not  try  to  modify  the  pump  or  use  non-original  parts.  This  damage  pump 
and cause warranty become invalid.   

Scheme 1    System configuration diagram (Example) 

 

 

 

1.

 

Level sensor 

2.

 

Check valve/filter 

3.

 

Pump 

4.

 

Release valve 

5.

 

Pressure gauge 

6.

 

Back pressure valve 

7.

 

Analog controller 

8.

 

Analog sensor 

9.

 

Target chemical tank 

10.

 

Pipe injector 

11.

 

Source chemical tank 

12.

 

Pulse damper 

13.

 

Flow sensor 

14.

 

Digital/analog flow 

controller 

15.

 

Drain valve pipe 

16.

 

Anit-siphon valve 

 

NOTICE

 

Not all of these devices 
are  installed.  In  most 
case  only  part  of  the 
components  will  be 
installed. 

100~240V 
AC 

OR 

Содержание EMP Series

Страница 1: ...A05G069A 1 YANGTECH ENGLISH 2106 EMP Series Multifunctional Electromagnetic Metering Pump EMP 3706 4210 5320 IP65 YANGTECH TECHNOLOGY CO LTD Taiwan O P E R A T I O N M A N U A L...

Страница 2: ...ign both in inlet and outlet joints Flow rate is more stable Rotary pump base which makes more convenient when installing Function of receiving 4 20mA or 0 10V industrial standard analog signal Option...

Страница 3: ...igh viscosity fluid may cause malfunction of pump Wear a chemical protect mask and gloves before repair or maintenance Please do not try to modify the pump or use non original parts This damage pump a...

Страница 4: ...lled or reduce piping length elbow or increase pipe diameter 4 Be aware that pressure discrepancy between input output hose should higher than the inner pressure loss of this pump otherwise overfeedin...

Страница 5: ...ases If operate pump continuously at high pulse rate and long period of time the temperature of case may reach 60 If you touch with bare hand you feel very hot but this is normal Yet if operation cond...

Страница 6: ...ital Fn B Batch Fn T Timer Fn MATERIAL CODE LIST Material Code AC AF BS VS SS Application Common Acid Strong Oxidative Acid Common Alkali Thick fluid Solvent 1 Valve Ball Ceramic Ceramic SUS316 SUS316...

Страница 7: ...Screw Set M5 25 2 Gasket 4 1 S S S S S 6 Operation Installing manual 1 S S S S S 7 PTFE Connector 1 2 PT 8 10mm 1 S 8 SUS304 Connector 1 2 8 10mm 1 S 9 PTFE Filter Check Valve 8 10mm 1 O O 10 PVC Fil...

Страница 8: ...ause resume pumping pressing longer than 5 seconds to abort batching Switch DISP When not in batch mode press this switch to change LED display within 3 unit3 Pause min ml min of setting range When no...

Страница 9: ...e adjust knob INDICATORS LAMPS Batch Fn sec Batch function in second Green light on The unit of LED display value is second Batch Fn Pulse Batch function in Pulse Green light on The unit of LED displa...

Страница 10: ...y pump is controlled by a P I D controller RUN STOP Toggle this switch to run stop the pump DISP Press this switch to change the unit of LED display Note1 invalid 3 External 0 10V Mode Optional In thi...

Страница 11: ...in code05 Suitable for batch dosing procedure and which is more convenient to execute in time count down RUN STOP Toggle this switch to run pause the pump Press over 5 seconds to abort a running batch...

Страница 12: ...d state switch can be used general mechanical relay may not be suitable for excessive noise Note1 Display changing order diagram In mode01 06 Press DISP Press DISP Pulse rate Pulse min of range Flow r...

Страница 13: ...ar to code05 Actually count down pulses cd06 cd07 For example if cd06 5000 and cd07 100 then count down pulses 5000 100 500000 pulses 2 If value excess 4 digit 1 3 decimal points will blink to hint ho...

Страница 14: ...N OFF time Note1 4 Volt 0 8V Low level Volt 3 0 60 0V Hi level B4 BLACK common for all signal of voltage current pulse on off B5 GREEN WHITE Power supply Output 5 0 V max 400mA with 0 5A auto reset fu...

Страница 15: ...8V Low Level Voltage 3 0V 60V High Level Signal Item Symbol Min Type Max Unit Timing Characteristic Low time TA 3 33 mSec HI time TB 3 33 mSec 1 Cycle TC 6 66 mSec Note2 An external switches circuit...

Страница 16: ...3 No transportation No power supply Turn on power Inlet pipe or filter blocked Clear pipe and or filter Diaphragm failure Replace with a new one Coil temp protector action Wait for protector to auto r...

Страница 17: ...if does then clean immediately Check pump of any leakage high temperature abnormal noise regularly and try to solve them according to page16 solutions table Tighten pump base fixing screws every year...

Страница 18: ...Pulse rate 200 Pulses min Pressure unit kg cm2 Note 1 Pipe altitude length number of valves liquid viscosity pressure all these factors variate discharge rate 2 For best accuracy calibrate discharge...

Страница 19: ...A05G069A 19 10 CONNECTOR DISASSEMBLE DIAGRAMS...

Страница 20: ...A05G069A 20...

Страница 21: ...A05G069A 21 Consult P 19 for other head sections...

Страница 22: ...URE Max kg cm2 PVC PVDF 10 0 7 0 3 5 SUS 3 STROKE mm 0 0 1 0 4 PULSE RATE pulse min 1 200 5 DIAPHRAGM Dia mm 37 42 53 6 JOINT HOSE ACH BSH 1 4 6 11mm PVC hose 3 0m VSH 3 8 9 5 15mm PVC hose 3 0m ACS B...

Страница 23: ...A05G069A 23 Manufacturer Sale YANGTECH YANGTECH TECHNOLOGY CO LTD Taiwan...

Отзывы: