A05G069A
11
5.
External
Fractional
Mode
(Optional)
Pumping frequency is a integer fraction to the external
voltage/on-off pulse signal. (suitable for
PC/Encoder/Probe/PLC devices which generate pulse
signal to control the pump)
For example
:
The pump works 1 pulse when accept 6
signals.
RUN/STOP*
:
Toggle this switch to run / stop the pump.
DISP.
:
Press this switch to change the unit of LED
display.
(Note1)
▲
▼
:
invalid.
6.
External
Synchronous
Mode
(Optional)
Pumping frequency is synchronous to the external
voltage/on-off pulse signal. (suitable for
PC/Encoder/Probe/PLC devices which generate pulse
signal to control the pump)
For example
:
The pump work 1 pulse when accept 6
signals.
RUN/STOP*
:
Toggle this switch to run / stop the pump.
DISP.
:
Press this switch to change the unit of LED
display.
(Note1)
▲
▼
:
invalid.
7.
Batch in
Time Mode
(Optional)
Pumping is controlled by a time count-down(By second)
procedure(a batch).The count-down timing can be set in
code05.
Suitable for batch dosing procedure and which is more
convenient to execute in time count-down.
RUN/STOP*
:
Toggle this switch to run / pause the pump.
Press over 5 seconds to abort a running
batch immediately.
DISP.
:
Press this switch to change the unit of LED
display.
(Note1)
▲
▼
:
invalid.
External batch control box configuration.
(Note2)
8.
Batch in
Pulse Mode
(Optional)
Pumping is controlled by a pulse count-down (By pulse)
procedure(a batch).The count-down pulses can be set in
code06.
Suitable for batch dosing procedure and which is more
convenient to execute in pulse count-down.
RUN/STOP*
:
Toggle this switch to run / pause the pump.
Press over 5 seconds to abort a running
batch immediately.
DISP.
:
Press this switch to change the unit of LED
display.
(Note1)
▲
▼
:
invalid.
External batch control box configuration.
(Note2)
9.
Timer Mode
(Optional)
Pump on /off repeatedly in a procedure that running for a
period of time then stop for a period of time.
For example you can set pump running for 3600 seconds(1
hour) and stop for 60 seconds(1 minutes) alternatively.
RUN/STOP
:
Toggle this switch to run / pause the pump.
External signal(6)
Pump action(1)