A05G069A
13
⚫
CODE DESCRIPTIONS
:
CODE
CODE NAME
UNIT
DESCRIPTIONS
01
Lowest Stroke
Rate
p/m
Default=0
,
Variation=0-80
(In Mode 4,5,6 is invalid)
02
Lowest Stroke
Rate
p/m
Default=200
,
Variation=100-200
(In Mode 4,5,6 is invalid)
03
Dividing
-
Default=01
,
Variation=1-9999
04
Multiple
-
Default=01
,
Variation=1-9999
05
Batch Timer
sec
Default=9999
,
Variation=0-9999
1.
Actually count-down timer = (cd05) * (cd07).
For example, if cd05=5000 and cd07=100
then count-down
timer=5000*100=500000(seconds)
2.
If value excesses 4 digits, 1~3 decimal points
will blink to hint how many digits wasn`t
shown up.
06
Batch Pulses
Counts
Pulse
Default=9999
,
Variation=0-9999
1.
This code is similar to code05. Actually
count-down pulses= (cd06) * (cd07). For
example, if cd06=5000 and cd07=100 then
count-down
pulses=5000*100=500000(pulses)
2.
If value excess 4 digit, 1~3 decimal points
will blink to hint how many digits wasn`t
shown up.
07
Code5,6,9,A
multiple
-
Default=1
,
Variation=1
,
10
,
100
,
1000
Valid in mode7,8,9
08
Flow Rate
At 200 Hz.
ml/min
Default=100
,
Variation=1-9999
Calibration procedure
:
1.
After installed pump and check all pumping
conditions are ready.
2.
Switch to mode1 and set pump rate up to 200
pulse/min.
3.
Use stopwatch and graduated cylinder to
measure the volume of pumping for 1 minute.
4.
Input the result to code08. This makes LED
unit display in ml/min accurately.
09
Mode9 Running
Time
sec
Default=60
,
Variation=1-9999
Set pump running period of mode9.
0A
Mode9 stopping
Time
sec
Default=60
,
Variation=1-9999
Set pump stopping period of mode9.
Содержание EMP Series
Страница 19: ...A05G069A 19 10 CONNECTOR DISASSEMBLE DIAGRAMS...
Страница 20: ...A05G069A 20...
Страница 21: ...A05G069A 21 Consult P 19 for other head sections...
Страница 23: ...A05G069A 23 Manufacturer Sale YANGTECH YANGTECH TECHNOLOGY CO LTD Taiwan...