![Yamato WG 1000 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/yamato/wg-1000/wg-1000_instruction-manual_905422007.webp)
4
Before Using this unit
Requirements for Installation
WARNING!
1. Always ground this unit
•
Connect the power plug to a receptacle with grounding connectors.
•
Do not forget to ground this unit, to protect you and the unit from electrical shock in case of
power surge. Choose a receptacle with grounding connectors as often as possible.
•
Do not connect the grounding wire to a gas pipe, or by means of a lightning rod or telephone
line. A fire or electrical shock will occur.
2. Choose a proper place for installation
•
Do not install this unit in a place where:
♦
Rough or dirty surface.
♦
Flammable gas or corrosive gas is generated.
♦
Ambient temperature 35
°
C and above or 5
°
C and below.
♦
Ambient temperature fluctuates violently.
♦
There is direct sunlight.
♦
There is excessive humidity and dust.
♦
There is a constant vibration.
♦
Not
horizontal
surface.
♦
The power source is instable.
•
Keep space around each product above the range shown below. Install units within sink
equipment if possible.
10cm or more
Front side
10cm or more
10cm
or more
10cm
or more
3. Do not use this unit in an area where there is flammable or explosive gas
•
Never use this unit in an area where there is
flammable or explosive gas. This unit is not
explosion-proof. An arc may be generated
when the power switch is turned ON or OFF,
and fire/explosion may result. (To know about
flammable or explosive gas, refer to Page 51
"List of Dangerous Substances".)