35
Maintenance Method
Washing of Distiller
Washing of Condenser
1. Pour detergent liquid into the cooling pipe of condenser.
(See Page 34 "Washing of boiler" for formulating detergent liquid.)
Detergent
Liquid
Hose
Connection
Port
2. If detergent liquid should flow out of hose connection port, seal with rubber stopper. Most fur can
be removed in 4 - 5 hours approximately.
3. Drain detergent liquid, and then wash enough with city water.
Handling of Detergent Liquid (also refer to Page 31 "Handling Precautions")
1. Wash the boiler and heater sooner. If the more scale is deposited, the more difficult is its removal,
which may cause decrease of distilled water sampling and damage to heater.
2. When washing is finished, drain detergent liquid out of the unit, and apply neutralization by
neutralizer (such as sodium hydroxide). In neutralization, check that it is neutral by use of pH test
paper, etc. (Principal component of scale detergent: Sulfamic acid and pH of water solution: Acidic
approximately 1)
3. In storing this detergent, seal the agent and store in cold and dark place avoiding high temperature
and humidity.
4. In handling this detergent, be sure to use protective tools (gloves, mask, and glasses).
5. When it is in contact with human body, wash it away with clean water.
6. Do not use empty container for beverage.
7. Do not allow detergent to directly flow into agricultural irrigation canal or fields because it causes
withering of rice crop.
Installation of boiler
1. Secure the boiler with the boiler securing band so that connection port of condenser is horizontal.
Check that the packing is contained in the cap nut, and then install the heater into the boiler with
letters "YK-W-3" faced up.
Packing
YK-W-3
Cap Nut
Heater
Boiler Securing
Band
Connection Port with
Condenser