SAFETY PRECAUTIONS
Warning & Cautions
Warning
Never operate equipment near combustible gases/fumes.
Do not install or operate SM series unit near flammable or explosive gases/fumes. Unit is NOT fire
or blast resistant. Negligent use could cause a fire/explosion. See “List of Hazardous Substances”
(P.40).
Always ground equipment.
Always ground this unit properly to avoid electric shock.
DO NOT operate equipment when abnormalities are detected.
If smoke or unusual odors begin emitting from unit, or if any other abnormalities are detected,
terminate operation immediately, turn off main power switch (Moldedcase circuit Breaker – “MCB”)
and disconnect power cable. Continued operation under such conditions may result in fire or
electric shock.
DO NOT operate with bundled or tangled power cable.
Operating unit with the power cable bundled or otherwise tangled, may cause power cable to
overheat and/or catch fire.
DO NOT damage power cable.
Damaging the power cable by forcibly bending, pulling or twisting may cause fire or electric shock to
the operator.
NEVER disassemble or modify equipment.
Attempting to dismantle or modify unit in any way, may cause malfunction, fire or electric shock.
DO NOT insert multiple power cables into a single outlet.
Inserting multiple cords into a single outlet, using branch outlets or extension cords, may cause
power cable to overheat and/or catch fire. Other issues may include a drop in voltage, which may
affect performance, resulting in failure to control or maintain proper temperatures.
DO NOT touch or block exhaust port
The exhaust port located on right side of unit emits steam during operation and becomes extremely
hot. Do not put hands or face near exhaust port and do not attempt to block or obstruct it in any way.
Equipment damage, explosion or personal injury may result.
Caution
DO NOT operate equipment during thunderstorm.
In the event of a thunderstorm, terminate operation and turn off main power switch (MCB)
immediately. A direct lightning strike may cause damage to equipment, or result in fire or electric
shock.