EAS00812
5. The water temperature indicator light fails
to operate.
1. Thermo unit
8
Remove the thermo unit from the cylin-
der head.
8
Connect the pocket tester (
Ω
×
1k) to
the thermo unit as shown.
Positive tester probe
J
J
J
J
J
black/blue
1
1
1
1
1
Negative tester probe
J
J
J
J
J
green/red
2
2
2
2
2
8
Measure the thermo unit resistance.
Thermo unit resistance
3.413~4.007k
Ω
Ω
Ω
Ω
Ω
at 80 °C
1.645~1.855k
Ω
Ω
Ω
Ω
Ω
at 100 °C
8
Is the thermo unit OK?
YES
NO
Replace the thermo unit.
2. Voltage
8
Connect the pocket tester (DC 20 V) to
the meter light coupler (wire harness
side) as shown.
Positive tester probe
J
J
J
J
J
green/red
1
1
1
1
1
Negative tester probe
J
J
J
J
J
ground
8
Set the main switch to “ON”.
8
Measure the voltage (DC 12 V) of green/
red
1
on the meter light coupler (wire
harness side).
8
Is the voltage within specification?
YES
NO
The wiring circuit from the
main switch to the thermo unit
connector is faulty and must
be repaired.
G/R B/L
DC20V
COOLING SYSTEM