–89–
OIL PUMP, CRANKCASE AND CRANKSHAFT
ENG
CAUTION:
INSPECTION
1. Measure:
S
Runout
Use the V-blocks and a dial gauge.
Out of specification
!
Replace or repair the
crankshaft.
Dial gauge:
90890-03097, YU-03097
Maximum runout:
C
1
: 0.03 mm (0.0012 in)
C
2
X
C
5
: 0.04 mm (0.0016 in)
C
6
: 0.03 mm (0.0012 in)
a
89.5 mm (3.52 in)
b
84.5 mm (3.33 in)
2. Measure:
S
Small end free play
a
Use the dial gauge.
Out of specification
!
Replace the defective
parts.
Small end free play:
0.8
X
1.0 mm (0.03
X
0.04 in)
S
Big end side clearance
b
Use the thickness gauge.
Out of specification
!
Replace the defective
parts.
Big end side clearance:
0.25
X
0.75 mm (0.01
X
0.03 in)
3. Inspect:
S
Crankshaft bearing
1
Pitting/ damage
!
Replace.
S
Stopper ring
2
Bends / damage
!
Replace.
S
Crankshaft oil seals
3
S
Impeller drive gear teeth
4
Wear / damage
!
Replace.
Lubricate the bearings immediately after ex-
amining them in order to prevent rust.
Содержание SXV70ERG
Страница 1: ...SUPPLEMENTARY SERVICE MANUAL ...
Страница 151: ... 145 CABLE ROUTING SPEC ...
Страница 153: ... 147 CABLE ROUTING SPEC ...
Страница 155: ... 149 CABLE ROUTING SPEC ...
Страница 157: ... 151 CABLE ROUTING SPEC ...
Страница 159: ... 153 CABLE ROUTING SPEC ...
Страница 161: ... 155 CABLE ROUTING SPEC ...
Страница 163: ... 157 CABLE ROUTING SPEC ...
Страница 165: ... 159 CABLE ROUTING SPEC ...
Страница 167: ... 161 CABLE ROUTING SPEC ...
Страница 169: ... 163 CABLE ROUTING SPEC ...
Страница 173: ... ੑ 01 06 0 8E ITP PRINTED ON RECYCLED PAPER ...