–114–
CARBURETORS
CARB
NOTE:
2. Adjust:
S
T.P.S. position
Adjustment steps:
S
Disconnect the T.P.S. coupler.
S
Connect the test coupler to the T.P.S.
S
Connect three dry cells (1.5 V
3 pcs.) in se-
ries to the test coupler.
Dry cells (–)
!
1
Dry cells (+)
!
2
S
Connect the digital multimeter to the test cou-
pler.
Digital multimeter (–) lead
!
1
Digital multimeter (+) lead
!
2
S
Measure the voltage
A
.
When measuring the voltage
A
be sure that the
test coupler is connected to the T.P.S.
S
Calculate the specified voltage
B
.
Specified voltage
B
= Voltage
A
(0.136)
S
Loosen the T.P.S. bolts
4
.
S
Connect the digital multimeter to the test cou-
pler.
Digital multimeter (–) lead
!
1
Digital multimeter (+) lead
!
3
S
Adjust the T.P.S. position to obtain the speci-
fied voltage
B
.
S
Tighten the T.P.S. bolts
4
.
S
Disconnect the test coupler and connect the
T.P.S. coupler.