background image

Display Operations

 Owner’s Manual

14

METER menu

Level meters for all input ports are shown at the left, and level meters for all output ports are shown at the right.
The upper part of the display shows icons that indicate the +48V ON, HPF ON, and GC ON status of the selected port.

Rio3224-D2

Rio1608-D2

Viewing the meters   

Head amp (HA) gain value settings

By turning the encoder with switch, you can adjust the HA gain value of the selected port. This can be adjusted in the 
range of –6 dB to +66 dB, in 1 dB units.

When there is an input or output of –3 dBFS or greater

When there is an input or output greater than –18 dBFS and not exceeding –3 dBFS

When there is an input or output greater than –60 dBFS and not exceeding –18 dBFS

NOTE

PEAK HOLD is always on, but you can clear PEAK HOLD for all ports by pressing the 
encoder with switch.

Содержание Rio1608-D2

Страница 1: ...EN Owner s Manual Keep This Manual For Future Reference AUDIO INTERFACE ...

Страница 2: ...n ON menu 17 About the status indication 17 SETUP menu 18 Status bar 20 INFORMATION menu 21 Other functions 22 About Connections 23 Daisy Chain Network 23 Star Network 23 Dante Network Settings and Audio Routing 24 Head Amp Control 24 Control from an Rio2 native Device 24 Head Amplifier Parameters That Can be Monitored and Controlled 24 Troubleshooting 25 Troubleshooting 25 Messages 26 Specificati...

Страница 3: ...perate normally or has been dropped UL60065_03 PRÉCAUTIONS CONCER NANT LA SÉCURITÉ 1 Lire ces instructions 2 Conserver ces instructions 3 Tenir compte de tous les avertissements 4 Suivre toutes les instructions 5 Ne pas utiliser ce produit à proximité d eau 6 Nettoyer uniquement avec un chiffon propre et sec 7 Ne pas bloquer les orifices de ventilation Installer l appareil conformément aux instruc...

Страница 4: ...rmined by turning the unit OFF and ON please try to elimi nate the problem by using one of the following measures Relocate either this product or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference relocate reorient the antenna If the antenna lea...

Страница 5: ...t hands Hearing loss Before connecting the device to other devices turn off the power for all devices Also before turning the power of all devices on or off make sure that all volume levels are set to the minimum Failing to do so may result in hearing loss electric shock or device damage When turning on the AC power in your audio system always turn on the power amplifier LAST to avoid hearing loss...

Страница 6: ...ot limited to MIDI data and or audio data is strictly prohibited except for your personal use About this manual The illustrations and LCD screens as shown in this manual are for instructional purposes only The company names and product names in this manual are the trademarks or registered trademarks of their respective companies About the organic EL display Organic EL displays are created using ex...

Страница 7: ... switch and buttons The internal head amps and parameters such as HPF can be viewed and controlled using only the Rio3224 D2 Rio1608 D2 unit itself The unit s internal errors and status are clearly indicated in the display Remotely Controllable Internal Head Amplifiers Internal head amp parameters can be remotely controlled from a compatible device such as the RIVAGE CL QL or TF series or from the...

Страница 8: ...turn off the EEE function EEE Energy Efficient Ethernet is a technology that reduces switch power consumption during periods of low network traffic It is also known as Green Ethernet or IEEE802 3az Precautions for Rack Mounting This unit is rated for operation at ambient temperatures ranging from 0 to 40 degrees Celsius When mounting the unit with other Rio unit s or other device s in an EIA stand...

Страница 9: ...disconnect a device to an INPUT while phantom power is applied Doing so can damage the connected device and or the unit itself To prevent possible damage to speakers make sure that power amplifiers and or powered speakers are turned OFF when switching phantom power ON or OFF We also recommend setting all digital mixing console output controls to minimum when turning phantom power ON or OFF Sudden ...

Страница 10: ...nnectors even if the individual input phantom power settings are ON In this case the 48V indicators will flash on channels for which phantom power is turned ON A AES EBU OUT Connectors 1 2 7 8 Rio3224 D2 only These XLR 3 32 type balanced connectors deliver AES EBU format digital output from the unit s corresponding output channels Each connector outputs 2 channel digital audio B OUTPUT 4 dBu Conne...

Страница 11: ...erCON CAT5e compatible RJ45 plugs is recommended Standard RJ45 plugs can also be used Use STP shielded twisted pair cable to prevent electromagnetic interference Make sure that the metal parts of the plugs are electrically connected to the STP cable shield by conductive tape or comparable means Connect only Dante compatible devices or GbE compatible devices including a computer D LINK ACT Indicato...

Страница 12: ...EC button and INC button appropriately 1 GC Gain Compensation Selecting menu items You can use any of the following methods to select the next lower menu Press the DEC button and INC button simultaneously While holding down the DEC button for 1 5 seconds or longer press the INC button You can use any of the following methods to select the next higher menu Hold down the DEC button and INC button si...

Страница 13: ...elected input port is highlighted at the same time the selected input port s LEDs 48V SIG PEAK are lit for one second The highlighted indication disappears when 10 seconds have elapsed without any front panel operation being performed When you once again press the DEC button or INC button the white frame cursor appears at the previous port position By long pressing the DEC button or INC button you...

Страница 14: ...meters Head amp HA gain value settings By turning the encoder with switch you can adjust the HA gain value of the selected port This can be adjusted in the range of 6 dB to 66 dB in 1 dB units When there is an input or output of 3 dBFS or greater When there is an input or output greater than 18 dBFS and not exceeding 3 dBFS When there is an input or output greater than 60 dBFS and not exceeding 18...

Страница 15: ...meters of all input ports upper line port name lower line 48V ON the port name of all output ports and the status of the unit itself In this menu you can turn on off the phantom power 48V of each input port Rio3224 D2 input ports Rio3224 D2 output ports status upper right Rio1608 D2 input ports left half output ports lower right status upper right Phantom power 48V settings By turning the encoder ...

Страница 16: ...e setting is actually specified and the flashing stops If you move the cursor while the parameter display area is flashing the change is discarded and the flashing also stops In the same way if you switch the menu selection while the parameter display area is flashing the change is discarded HPF F menu This shows the HPF parameters of all input ports upper line port name middle line HPF ON status ...

Страница 17: ...he menu selection while the parameter display area is flashing the change is discarded About the status indication The upper line of the status area shown in each menu shows the Dante device label of the unit the lower line shows an ERROR INFORMATION icon and corresponding message only if an ERROR INFORMATION state occurs Rio3224 D2 output ports status upper right Rio1608 D2 input ports left half ...

Страница 18: ...ng also stops In the same way if you switch the menu selection while the parameter display area is flashing the change is discarded Table of parameters The following table shows the items that can be selected the description of the parameters and the values that can be specified is the default value Item parameter Description Values UNIT ID Specifies the ID of the unit Y000 0 Y07F 127 Y001 START U...

Страница 19: ...en STATIC IP is specified 0 0 0 0 In the case of AUTO the current value is shown DEFAULT GW Specifies the DEFAULT GATEWAY when STATIC IP is specified 0 0 0 0 In the case of AUTO the current value is shown DIMMER Specifies the time after which the organic EL display goes dark when the unit has not been operated for a time In order to extend the life of the organic EL display it is designed to go da...

Страница 20: ... an operation from the Rio2 native device or power cycle this unit Upper line Shows the ERROR icon or the INFORMATION icon If both ERROR and INFORMATION have occurred the ERROR icon takes priority and is shown If neither ERROR nor INFORMATION has occurred nothing is displayed If ERROR or INFORMATION have occurred the content is shown in the second line of the status display area within each HA scr...

Страница 21: ...rovides a description of the items that can be selected and the values that can be set SYSTEM information display example DANTE information display example If this unit s Dante Device Lock is enabled or if AES67 mode is enabled the respective icon is shown in the upper right LOG information display example By turning the encoder you can scroll the displayed content up or down REPORT information di...

Страница 22: ...the panel lock state by simultaneously holding down the DEC button INC button and the encoder with switch for approximately three seconds This state is maintained even if the unit is power cycled To defeat the panel lock state simultaneously hold down the DEC button INC button and the encoder with switch once again for approximately three seconds Brightness adjustment While this unit is operating ...

Страница 23: ...ou to configure a wide band large scale network We recommend a network switch that features various functions to control and monitor the network such as Qos the ability to assign priority to data flows e g clock synchronization or audio transmission on certain data circuits With this topology it is common to configure a redundant network so that an unexpected network problem will not affect any au...

Страница 24: ... be controlled remotely from an Rio2 native device such as a RIVAGE CL QL or TF series product The connected Rio2 native device displays the model name and UNIT ID number of the corresponding Rio unit to be controlled If you plan to connect to a Rio2 native device to monitor and control the head amplifiers refer to the owner s manual for the corresponding device Head Amplifier Parameters That Can ...

Страница 25: ...e level No sound is heard The cables are not connected properly Connect the cables properly The SETUP menu s START UP MODE setting is REFRESH but the Rio2 native device has not started up Start the Rio2 native device to send the setting to the Rio Output is muted Unmute the output on the Rio2 native device The head amp cannot be controlled The Rio has not been mounted on the RACK of the Rio2 nativ...

Страница 26: ... The supply of power to either power supply A or B has been interrupted Check that the power supply cable is connected If checking does not resolve the problem contact a Yamaha service center GIGABIT NETWORK LINK FAILED SWITCHED TO 100Mbps or 10Mbps Dante is not operating at 1 Gbps Check the link status Try plugging into a different network switch or a different port Alternatively try using a diff...

Страница 27: ...in the Dante module The device has malfunctioned please contact a Yamaha service center ILLEGAL MAC ADDRESS E00 04 Because the MAC Address setting has been damaged communication is not possible The device has malfunctioned please contact a Yamaha service center UNIT FAN HAS MALFUNCTIONED E00 06 The cooling fan has stopped Check whether a foreign object might be caught in the fan If this does not s...

Страница 28: ...ion is occurring via the SECONDARY port Check the circuit that is connected to the PRIMARY port ERROR OCCURRED AT SECONDARY PORT E01 08 In the case of a redundant network a problem has occurred in the circuit that is connected to the SECONDARY port Check the circuit that is connected to the SECONDARY port DANTE WORD CLOCK MASTER Functioning correctly as the word clock master This indicates that th...

Страница 29: ... Less than 0 05 20 Hz 20 kHz 4 dBu into 600Ω Fs 48 kHz Less than 0 05 20 Hz 40 kHz 4 dBu into 600Ω Fs 96 kHz INPUT to OUTPUT Input Gain Min Hum Noise 2 128 dBu typ Equivalent Input Noise Input Gain Max 88 dBu Residual output noise ST master off Dynamic Range 112 dB typ DA Converter 108 dB typ INPUT to OUTPUT Input Gain Min Crosstalk 1 kHz 100 dB 3 adjacent INPUT OUTPUT channels Input Gain Min Dime...

Страница 30: ... 62 dBu 0 616 mV 42 dBu 6 16 mV XLR 3 31 type Balanced 1 6 dB 10 dBu 2 45 V 30 dBu 24 5 V INPUT 17 32 2 66 dB 7 5 kΩ 50 600Ω Mics 600Ω Lines 62 dBu 0 616 mV 42 dBu 6 16 mV XLR 3 31 type Balanced 1 6 dB 10 dBu 2 45 V 30 dBu 24 5 V Output Terminals Actual Source Impedance For Use With Nominal Max Output Level Select SW 1 Output Level Connector Nominal Max before clip OUTPUT 1 8 75Ω 600Ω Lines 24 dB ...

Страница 31: ...mm The contents of this manual apply to the latest specifications as of the publishing date To obtain the latest manual access the Yamaha website then download the manual file 480 220 11 5 6 367 5 350 Rio3224 D2 132 480 11 5 6 367 5 350 Rio1608 D2 ...

Страница 32: ...MEMO ...

Страница 33: ...MEMO ...

Страница 34: ......

Страница 35: ...0 210 6686168 SWEDEN FINLAND ICELAND Yamaha Music Europe GmbH Germany filial Scandinavia JA Wettergrensgata 1 400 43 Göteborg Sweden Tel 46 31 89 34 00 DENMARK Yamaha Music Denmark Fillial of Yamaha Music Europe GmbH Tyskland Generatorvej 8C ST TH 2860 Søborg Denmark Tel 45 44 92 49 00 NORWAY Yamaha Music Europe GmbH Germany Norwegian Branch Grini Næringspark 1 1332 Østerås Norway Tel 47 6716 7800...

Страница 36: ...Published 12 2017 IPES A0 2017 Yamaha Corporation Manual Development Group Yamaha Downloads http download yamaha com Yamaha Pro Audio global website http www yamahaproaudio com ZW39210 ...

Отзывы: