Display Operations
Owner’s Manual
22
Other functions
Initializing to the factory-set state
If you turn on the power while holding down both the
(DEC) button and
(INC) button, you can enter a mode that
returns this unit’s settings to their factory-set state. This is the same as if you use the SETUP menu to select INITIALIZE
→ FACTORY PRESET.
Initializing the HA parameters
If you turn on the power while holding down only the
(DEC) button, you will enter a mode that returns the HA
parameter values to their factory-set state.
This is the same as if you use the SETUP menu to select INITIALIZE → HA PARAMETERS.
Initializing the Dante parameters
If you turn on the power while holding down only the
(INC) button, you will enter a mode that returns the Dante
parameter values to their factory-set state. This is the same as if you use the SETUP menu to select INITIALIZE →
DANTE SETTINGS.
Factory-set initial values
The following table shows the factory-set initial values.
*1
nnnnnn is the lowest six digits of the Dante Primary MAC Address
Panel lock
While this unit is operating, you can put it in the panel lock state by simultaneously holding down the
(DEC) button,
(INC) button, and the encoder with switch for approximately three seconds. This state is maintained even if the unit
is power-cycled. To defeat the panel lock state, simultaneously hold down the
(DEC) button,
(INC) button, and the
encoder with switch once again for approximately three seconds.
Brightness adjustment
While this unit is operating, simultaneously hold down the
(DEC) button and
(INC) button for at least 1.5 seconds,
and turn the encoder with switch to adjust the brightness of the display (BRIGHTNESS).
Parameter
Initial value
SETUP
UNIT ID
Y001
START UP MODE
REFRESH
SECONDARY PORT
DAISY CHAIN
FAN SPEED
LOW
NETWORK MODE
AUTO
IP ADDRESS
(determined by DHCP or link local)
SUBNET MASK
(determined by DHCP or link local)
DEFAULT GW
(determined by DHCP or link local)
DIMMER
3 min
ERROR MESSAGE
LIGHT OFF
BRIGHTNESS
70%
HA Parameters
HA GAIN
–6 dB
+48V
Off
HPF
Off, 80.0 Hz
GAIN COMPENSATION
Off, –6 dB
DANTE Settings
Sample Rate
96 kHz (slave), Pull-up/down = None
Latency
1.0 ms
Encoding
PCM 24 bit
Dante Redundancy
Switched (depends on the setting of SETUP
SECONDARY PORT)
IP Address
Auto
Device Label
Y001-Yamaha-Rio3224-D2-nnnnnn *1
Y001-Yamaha-Rio1608-D2-nnnnnn *1
Channel Label
<channel number>
AES67 Mode
Disabled
Device Lock
Unlock