INSTALLATION RECOMMENDATIONS
We recommend that the system is adjusted so that arrivals from MAIN SYSTEM array and
SUB speakers are coincident at a fairly distant listening position (typically further than the
mixing position).
Geometrical alignment
In the example below,
r
1
being the smaller distance from MAIN SYSTEM array to listener
position, and
r
2
being the smaller distance from SUB to listener position, the distance
difference is then
r
1
–
r
2
(specified meters or feet).
•
r
1
>
r
2
, the delay should be set on the SUB
NXAMP
Powered TDcontroller(s).
•
r
1
<
r
2
, the delay should be set on the MAIN SYSTEM
NXAMP
Powered
TDcontroller(s)
To convert the result in time delay (specified in seconds), apply:
∆
t = (
r
1
-
r
2
)/C
r
1
and
r
2
in meters, C (sound speed)
≈
343 m/S.
The delay parameter is set in MENU “Delay” (See above).
However, it is a safe practice to double-check geometrical alignment with a proper
acoustical measurement tool.
1200 mm
[47.24"]
750 mm
[29.53"]
750 mm
[29.53"]
1200 mm
[47.24"]
750 mm
[29.53"]
750 mm
[29.53"]
1200 mm
[47.24"]
750 mm
[29.53"]
750 mm
[29.53"]
r
2
r
1
Measuring and aligning phase in the overlapping region
Microphone must be set on the ground
, at a fairly distant listening position (typically
further than the mixing position).
Phase must be measured with a wrapped display, and measurement must be properly
windowed on signal arriving time (same window for SUB and MAIN SYSTEM). When
measurement is synchronized to the system-microphone distance, phase can be clearly
displayed in the low-frequency range.