3-12
INSP
ADJ
E
ELECTRICAL
2. Inspect:
●
Electrolyte level
Low
→
Add distilled water.
The electrolyte level should be
between the upper
a
and lower
b
level marks.
CAUTION:
Use only distilled water. Other types of
water contain minerals which are harmful
to batteries.
Filling steps:
●
Remove each filler cap.
●
Add distilled water.
●
When the electrolyte level reaches the
upper level mark, allow the cell to
stand for 20 minutes. If the electrolyte
level drops, add more distilled water
so the level reaches the upper level
mark.
3. Inspect:
●
Specific gravity
Out of specification
→
Charge.
Specific gravity at 20 ˚C (68 ˚F):
1.28
Charging current:
1.9 amps
×
10 hrs (68.4 kC)
4. Install:
●
Filler caps
CAUTION:
Before installation, rinse off any fluid from
the battery box and battery and make sure
that the battery is dry before installing it.