Maintenance
95
TIP:
Inspect ground leads attached to external
anodes on equipped models. Consult a
Yamaha dealer for inspection and replace-
ment of internal anodes attached to the pow-
er unit.
EMU29324
Checking battery (for electric start
models)
WARNING
EWM01903
Battery electrolyte is poisonous and
caustic, and batteries generate explosive
hydrogen gas. When working near the
battery:
Wear protective eye gear and rubber
gloves.
Do not smoke or bring any other source
of ignition near the battery.
The procedure for checking the battery var-
ies for different batteries. This procedure
contains typical checks that apply to many
batteries, but you should always refer to the
battery manufacturer’s instructions.
NOTICE
ECM01921
A poorly maintained battery will quickly
deteriorate.
1. Check the electrolyte level.
2. Check the battery’s charge. If your boat
ZMU02924
ZMU03664
ZMU06420
ZMU06421