TRBL
SHTG
Troubleshooting
9-1
62Y5A11
NOTE:
• To diagnose a mechanical malfunction, use the troubleshooting charts pertaining to the trouble
located in this chapter. Also, when checking and maintaining the outboard motor, see Chapters 4–
8, to check the part necessary to carry out safety maintenance.
• Check that all electrical connections are tight and free from corrosion, and that the battery is fully
charged to 12 V.
Power unit
9
Symptom: Engine does not crank.
• Check the starting system.
• Check the power unit.
Check that the gearshift is in the
neutral position.
Check the neutral switch for
continuity.
Check the engine start switch
for continuity.
Check the engine shut-off
switch for continuity.
Is the gearshift
in neutral?
Is there conti-
nuity?
Is there conti-
nuity?
Set it to the neutral position.
Replace the neutral switch.
Replace the engine start switch.
Yes
Yes
Yes
No
No
No
Continued on next page.
Содержание F100B
Страница 1: ...SERVICE MANUAL 60C 28197 5D 11 290429 F100B F100C ...
Страница 52: ...SPEC Specifications 2 17 60C5D11 MEMO ...
Страница 162: ...LOWR Lower unit 6 15 60C5D11 Drive shaft and lower case F100B 6 ...
Страница 172: ...LOWR Lower unit 6 25 60C5D11 Shimming F100B 6 T3 B4 59 0 A3 A1 B2 T2 15 8 A2 34 0 B1 T1 F R P B3 S60C6305 ...
Страница 190: ...LOWR Lower unit 6 43 60C5D11 Drive shaft and lower case F100C 6 ...
Страница 200: ...LOWR Lower unit 6 53 60C5D11 Shimming F100C 6 ...
Страница 209: ...60C5D11 7 2 1 2 3 4 5 6 7 8 9 MEMO Special service tools ...
Страница 210: ...BRKT Bracket unit 7 3 60C5D11 Tiller handle 7 ...
Страница 212: ...BRKT Bracket unit 7 5 60C5D11 ...
Страница 214: ...BRKT Bracket unit 7 7 60C5D11 ...
Страница 244: ...BRKT Bracket unit 7 37 60C5D11 Gear pump F100B 7 ...
Страница 321: ...62Y5A11 TRBL SHTG 1 2 3 4 5 6 7 8 9 Troubleshooting Power unit 9 1 Bracket unit 9 11 Electrical systems 9 15 ...
Страница 341: ......
Страница 343: ......
Страница 344: ...YAMAHA MOTOR CO LTD Printed in the Netherlands Jun 2001 0 5 1 CR F100BET F100CET E ...