POWR
5-17
61U5H11
Power unit
1.
Remove the CDI unit cover, start-in-gear
protection cable
1
, then remove the
manual starter and starter pully (MH,
WH).
2.
Disconnect the negative battery cable
2
,
positive battery cable
3
and PTT motor
lead
4
.
å
∫
å
WH, E
∫
ET
3
2
61U50350
9.
Pull the manual starter handle several
times in the direction of the arrow to
check that the sheave drum turns
smoothly and to check the starter rope for
slack. Repeat steps 3–8 if necessary.
NOTE:
Align the mark
f
on the stopper with guide,
and then turn the sheave drum.
10. Pull the manual starter handle complete-
ly, then measure the starter rope length.
If the starter rope length is out of specifi-
cation, refer to the step 7 and adjust the
starter rope by rewind times.
Removing the power unit
NOTE:
It is recommended to loosen the flywheel
magnet nut before removing the power unit to
improve working efficiency.
61U50080
f
61U50090
g
Starter rope length
g
:
(Reference data)
1,700–1,900 mm (66.9–74.8 in)
1
69D50160
3
2
4
61U50360
61U5H11_05_1 06.2.10 17:22 Page 20
Содержание E115A
Страница 1: ...115B SERVICE MANUAL 61U 28197 5H 11 140B E115A E115A 115B 140B ...
Страница 4: ......
Страница 79: ...61U5H11 4 18 9 8 7 6 5 4 3 2 1 MEMO ...
Страница 136: ...POWR 5 55 61U5H11 Power unit MEMO ...
Страница 159: ...61U5H11 6 22 9 8 7 6 5 4 3 2 1 Shimming Shimming 6G46090E T3 M3 M4 M1 M2 T1 T2 F R P ...
Страница 255: ......
Страница 256: ...YAMAHA MOTOR CO LTD Printed in Japan Oct 2005 1 2 1 E_1 Printed on recycled paper E115A 115B 140B ...