ELEC
8-11
61U5H11
Electrical system
Checking the starter relay
(WH, E, ET)
1.
Remove the starter relay
1
.
2.
Connect the digital circuit tester leads to
the starter relay terminals.
3.
Connect the positive battery terminal to
the brown (Br) lead
2
, also connect the
negative battery terminal to the black (B)
lead
3
, and then check for continuity
between the starter relay terminals.
Replace the starter relay if there is no
continuity.
4.
Check that there is no continuity between
the starter relay terminals after discon-
necting a battery terminal from the brown
2
or black lead
3
. Replace the starter
relay if there is continuity.
3
2
6G480196
1
61U80030
Checking the neutral switch (WH)
1.
Check the neutral switch for continuity.
Replace if there is no continuity.
6F680140
a b
Br
Br
Switch Lead
color
position
Brown (Br)
Brown (Br)
Free
a
Push
b
61U5H11_08 05.10.7 3:02 PM Page 12
Содержание E115A
Страница 1: ...115B SERVICE MANUAL 61U 28197 5H 11 140B E115A E115A 115B 140B ...
Страница 4: ......
Страница 79: ...61U5H11 4 18 9 8 7 6 5 4 3 2 1 MEMO ...
Страница 136: ...POWR 5 55 61U5H11 Power unit MEMO ...
Страница 159: ...61U5H11 6 22 9 8 7 6 5 4 3 2 1 Shimming Shimming 6G46090E T3 M3 M4 M1 M2 T1 T2 F R P ...
Страница 255: ......
Страница 256: ...YAMAHA MOTOR CO LTD Printed in Japan Oct 2005 1 2 1 E_1 Printed on recycled paper E115A 115B 140B ...