61U5H11
7-40
9
8
7
6
5
4
3
2
1
PTT motor
c
C
9
Do not pull the PTT motor leads out from
the stator.
9
Do not touch the bimetal
a
, otherwise
the operation of the circuit breaker can
be affected.
Checking the PTT motor
1.
Check the commutator. Clean with 600 –
grit sandpaper and compressed air if
dirty.
2.
Measure the commutator diameter.
Replace the armature if below specifica-
tion limit.
3.
Measure the commutator undercut
b
.
Replace the armature if below specifica-
tion limit.
4.
Check the armature for continuity.
Replace if not shown as below chart.
6G480220
a
Commutator standard
diameter
a
:
22.0 mm (0.87 in)
Wear limit:
21.0 mm (0.83 in)
6F680180
b
Commutator standard
undercut
b
:
1.35 mm (0.053 in)
Wear limit: 0.85 mm (0.033 in)
6S370140
c
d
e
Armature continuity
Commutator segments
c
Continuity
Segment
c
–
No continuity
Armature core
d
Segment
c
–
No continuity
Armature shaft
e
61U5H11_07_1 06.2.13 1:24 PM Page 43