4. PROCEDURE FOR MEASUREMENT OF “CO” EMISSION LEVEL
4.1
IMPORTANT :
“CO” Measurement Equipment must be duty calibrated.
4.2
Check for “NO LEAKAGE” from Exhaust System.
4.3
Starter Lever should be in OFF position.
4.4
All Electricals should be in OFF position.
4.5
Set the Idle speed of the Engine in warmed up condition of Motorcycle as specified.
4.6
Insert the Sampling probe of the Exhaust Gas Analyser inside the Exhaust Muffler of the
Motorcycle.
4.7
•
If the reading is within specified limits then it is acceptable.
•
If the reading exceeds the norm of 3.5% (by volume) have it adjusted by YMI Authorised
Dealer.
4.8
YMI serves you through an extensive network of
•
Authorised Dealers
•
Authorised Service Points.
•
Trained Private Workshop (Garage) Owner’s.
‘CO’ EMISSION LEVEL MEASUREMENT
4
MODEL
IDLE R.P.M.
1300 - 1500 RPM
CRUX-S