About the COMMANDS
214
Chapter 9 COMMAND
• A5000/A4000
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Knob 1
Same function as Cursor
q
(page 213).
Knob 3
[
Turn] From SampleBank
Selects the source Sample Bank for the freeze operation.
All Sample Banks in memory can be selected.
Knob 4
[
Turn] Loop Mode
Sets the Loop Mode. When the Freeze command is exe-
cuted the Loop Mode settings of all samples within the
target Sample Bank are set accordingly. All Loop Modes
can be selected (page 123).
• This parameter can only be used when the Freeze
Type is set to SampleBank&LpMode
→
Samples or
LpMode
→
Samples.
Knob 5
Same function as Cursor
q
(page 213).
REGISTER
[COMMAND/EXIT] Button
→
Knob 1 to highlioght display line 2
→
Press Knob 3.
This command registers the initial EFFECT, SETUP, and
CONTROL function settings which will be recalled whenever
the power is turned on or when a program is initialized (page
217) from the specified source program. It also registers the
initial sample parameters which will be recalled whenever a
sample is recorded (page 151) or imported (page 175) from
the specified source sample.
• If, for example, you want reverb to be ON whenever the power is
turned on or a program is initialized, use the following procedure:
1.
Create a program that uses reverb.
2.
Go to the REGISTER page and select Program as the
Regist Type.
3.
Select the program created in step
1
as the Source
Program, and set the Regist Source EFFECT parame-
ter to SourcePgm.
4.
Execute the Register command.
• The registered settings are retained even when the power is turned
off.
• When new settings are registered the previously registered settings
are erased and overwritten.
[Operation]
1.
Select the Regist Type (page 215).
2.
Make other settings as required.
3.
Press Knob 1 (EXEC) or Knob 5 (EXEC&CONT), and the register
confirmation display will appear. Press Knob 5 (YES) to execute
the register operation.
• If Knob 1 (EXEC) is used to execute the command, the display
previous to the command menu will be recalled after execution
has finished. If Knob 5 (EXEC&CONT) is used to execute the
command, the register display will be retained so you can con-
tinue and perform further register operations.
Knob 1
[
Turn] Cursor
Positions the cursor.
[
Press] EXEC
Press this knob to call the register confirmation display.
Press Knob 5 (YES) to actually execute the register oper-
ation.
Cursor
w
(when the FreezeType is SampleBank&LpMode
→
Sam-
ples, SampleBank
→
Samples, and LpMode
→
Samples)
Knob 1
Knob 2
Knob 3
Knob 4
Knob 5
Turn
action
Cursor
—
From
SampleBank
Loop Mode
—
Press
action
EXEC
—
—
—
EXEC&CONT
w
Cursor
Cursor
q
Knob 1
Knob 2
Knob 3
Knob 4
Knob 5
Turn
action
Cursor
Regist Type
—
—
—
Press
action
EXEC
—
—
—
EXEC&CONT
q
Cursor
Содержание A4000
Страница 1: ......
Страница 30: ...Sound Check 30 Chapter 1 Setting Up A5000 A4000 ...
Страница 116: ...PLAY CONTROL 116 Chapter 4 PLAY Mode A5000 A4000 ...
Страница 296: ......