EN_installation manual_Toro_v1.6
- 11 -
To ensure electrical safety, the power cable is double insulated and the Toro electronic parts operate at
a safe low voltage (max 15V). All electronic parts are incorporated in the Toro construction and stored
waterproof (IP65).
- The Toro needs to be powered by 230V AC
- The power cable (ground cable, possibly in protective tube) should be lead through the Toro
construction to the mounting panel with the electronic parts
- The power cable needs to be connected to the IP44 power socket on the mounting panel by a
certified electronic engineer
- For connecting the Toro, only the supplied Ecomate to power net cable may be used between the
power socket and the safety transformer
- The connection value of the Toro is 230V , 2A
- The power cable needs to be assembled in the blue power norm 2P + earth contact box of class
IP44 (also known as ‘camping socket’). This power supply MUST be assembled on separate group
with a 30mA ground fault circuit interrupter (GFCI), fused on 10A or 16A. For example with a
protection box of the type: Merlin Gerin, MG 10A-B 19791 DPNA VIGI 30MA
6 Electronics: Power
Master goal - Back view
Connection ground cable
to the IP44 power socket
Power (ground) cable. 230V
AC on seperated group
with ground fault circuit
interrupter