PIR sleep feature
The PIR has a built-in sleep timer to save battery
power. If there is no movement in front of the PIR for
1 minute, the PIR will become ready to signal and
movement will now be reported. The PIR will sleep
for 1 minute after. Any movement detected in sleep
time will not be reported and will extend the sleep
period by 1 minute.
Walk test
This allows you to test the system without
causing an alarm.
1
Press # followed by your Program code.
2
Press OK.
3
Select Walk Test .
4
Press OK and wait for control unit self test period
to finish.
¥ Walk around protected areas in front of PIR s and
open doors/windows protected by door contacts.
¥ If the control unit receives a signal, it will sound a
chime and the display will show the sensor and
zone number which has been tested.
¥ The message will be displayed until being
replaced by another test signal.
¥ Pressing the
key, will return to programming
menu.
¥ If left in walk test, the control unit will revert back
to Alarm off after 5 minutes.
Testing the siren
The siren can be tested by arming and disarming
the system, the siren will respond as follows:
¥ When the control unit is armed the siren will beep
once (if siren confirm is switched on) and will flash
after the Exit delay period has expired.
¥ When the control unit is disarmed, the siren will
give two short beeps (if siren confirm is switched
on) and will flash from side to side twice.
Testing the system
Testing the system should be done on a regular basis and after any alterations.
15
5